36
Function No. : 071
Function Name : Feed plate control
The operation control of the feed plate is set as shown in the table below.
071. FF Number
Setting
Value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
·
·
·
·
31
DEFAULT
Item
Upper Reed Plates
Upper feed plate
control with pedal
Upper feed plate controls
for pause
Level 2
strokes
Single body feed plate
Single body feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Two part feed plate
Unused
Unused
Unused
Unused
Right feed plate lowered first
Right feed plate lowered first
Left feed plate lowered first
Left feed plate lowered first
Right feed plate lowered first
Feed plate raised and stopped
Feed plate raised and stopped
Both parts raised and stopped
Left side raised and stopped only
Right side raised and stopped only
Both parts raised and stopped
Left side raised and stopped only
Right side raised and stopped only
Both parts raised and stopped
Left side raised and stopped only
Both parts raised and stopped
Right side raised and stopped only
Both parts raised and stopped
×
○
×
×
×
○
○
○
○
○
○
○
×
[Contents] The feed plate and operation orders are set according to what kind of machine
you have. Set the control order for paused pattern data operations and pedal
control of the upper feed plate.
[Caution] When the ‘pause during operation’code appears, set the upper feed plate
control at Function Number 061, “Feed Plate Control When Paused”first.
In the item of 2-step stroke, ○ means the 2-step stroke can be used, and × means it cannot be
used. In case of a motor type, the left-right separate type feed plates are not in use.
Caution