Function No. : 087
Function Name: Deleting Other Designs When Opening New Design
This function is to set whether other designs will be deleted when a new design is opened.
Design Saving in Flash Memory (default)
Deleting Designs from Flash Memory
[Contents] When a design is opened from a USB flash drive, save the designs opened from
Flash Memory. If other designs need to be opened continuously, they could be
saved in Flash Memory and it might cause memory save shortage. Therefore it
would be better to save up to 16 designs (100kbyte per design).
[Contents] When designs are opened from Flash Memory, the designs will be deleted
consecutively one by one. Therefore, whenever designs are opened from Flash
Memory continuously, the current design will remain saved, while other designs
are deleted.
087. DsgnOpnCtrl
1) SAVE
2) DELETE
Setting
Value
Function No. : 089
Function Name: Jump Speed Setting
This function is to set the jump speed.
It sets the slowest jump speed.
[Contents]
It sets the medium jump speed (default).
[Contents]
It sets the highest jump speed.
[Contents]To shorten the working hours, set the highest jump speed. It could save plenty
of time.
089. Jump Speed
1) SLOW_SPEED
2) MIDDLE_SPEED
3) FAST_SPEED
Setting
Value
Function No. : 088
Function Name: Setting the Safety Mode
TThhiiss iiss aa ffuunnccttiioonn ttoo ooffffeerr ssaaffeettyy ttoo uusseerrss..
Not in use (at the time of the factory release)
[Contents] The safety mode has not been set.
088. Safety Mode
1) DISABLE
Setting
Value
Used.
[Contents] When the function is set, if the sewing machine is stopped because of
emergency stop, thread sensing or pause code, the sewing machine remains
stalled even when the pedal start switch or the clamp up/down switch is
pressed or when any OP box keys are entered. To cancel the safety mode,
press “EXE”on the left bottom of the OP Box. When the “EXE”key is pressed,
the sewing machine can be operated again.
2) ENABLE