44
Function No. : 090
Function Name : Emergency Stop Switch Setting During Jump Motion
This function is to set whether the emergency stop switch is used during the jump motion.
The emergency stop switch is not used during the jump motion (default).
The emergency stop switch is used during the jump motion.
[Contents] If the emergency stop switch is pressed during the jump motion, the emergency
stop is not activated. When the jump motion is completed, the emergency stop
is conducted.
[Contents] If the emergency stop switch is pressed during the jump motion, the emergency
stop is immediately activated.
090. Jump EM_SW
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 091
Function Name : Presser Foot Lift Setting During Jump Motion
(depending on the presser foot motor specifications)
The function is to set whether the presser foot is lifted during the jump motion.
The presser foot lift function is not used during the jump motion.
The presser foot lift function is used during the jump motion (default).
[Contents] During the jump motion, the jump motion is conducted without the lift of the
presser foot. If the interference of the presser foot is not concerned during the
jump motion, this function can be used to save work hours.
[Contents] During the jump motion, the jump motion is conducted with the presser foot
lifted. If the interference of the presser foot occurs during the jump motion, this
function can be used.
091. Jump PF Ctrl
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 092
Function Name : Presser Foot's Thickness Difference Control Code Setting
(depending on the presser foot motor specifications)
This function is to set whether the presser foot's thickness difference control code value applied
to the sewing data is used or not.
The presser foot's thickness difference control code is not used.
The presser foot's thickness difference control code is used (default).
[Contents] The presser foot's thickness difference control code value, which is created when
the sewing data is made, is not used. Sewing can be conducted without the
presser foot's feed for fabric thickness difference control.
[Contents] The presser foot's thickness difference control code value, which is created when
the sewing data is made, is used. Sewing can be conducted while the presser
foot ascends or descends by the user set feed.
092. PF Code Ctrl
1)DISABLE
2) ENABLE
Setting
Value
Summary of Contents for SPS/E-5050 Series