46
Function Name : Clamp Height Setting (limited to the clamp motor-equipped models)
User sets the clamp height.
User sets the clamp height (default value: “000"mm)
[Contents] Use the direction keys (#2, #8) to choose the clamp height and save the
value. When the keys are pressed, the clamp position can be checked at a
glance. After saving, the clamp descends to and stops at the set position.
[Contents]
Large patterns (SPS/E-5050, 8050) does not have the motor enabling delicate clamp
adjustment. Therefore, this function cannot be used.
096. Clamp Range
000~350[0.05mm]
Setting
Value
Function Name : Presser Foot Height Setting
(limited to the presser foot motor-equipped models)
User sets the presser foot height.
User sets the presser foot height (default value: “000" mm)
[Contents] Use the direction keys (#2, #8) to choose the clamp height and save the
value. When the keys are pressed, the clamp position can be checked at a
glance. After saving, the clamp descends to and stops at the set position.
[Contents]
Large patterns (SPS/E-5050) does not have the motor enabling delicate clamp
adjustment. Therefore, this function cannot be used.
097. PF Range
000~200[0.05mm]
Setting
Value
Function No. : 096
Function No. : 097
Summary of Contents for SPS/E-5050 Series
Page 2: ......