Function Name : Needle bar upper stop position setting
When the motor stops, the function makes the needle bar stop at the pre-set position. (applied to
the direct drive model only)
The value can be set at the range of 0~360
。
(Default value: 97
。
)
[Contents] The needle bar position angle can be changed as below. The spinning of the hand
pulley clockwise shows the change in angles. At the changed position, press the
ENTER key to set the current angle value.
By nature of SPS/E-5050 and 8050, the head is lifted, and the main shaft motor is
attached at the angle of 90
。
. Therefore, the default value is set at 97
。
.
126. Up Stop Pos
0~360[degree]
Setting
Value
Function No. : 126
Function No. : 125
Function Name: Air Bag Mode Setting (Air Bag specification)
Function to open the air-compressed thread release unit when users move without trimming at the jump
section.
Not use the Air Bag Mode (Factory shipment state)
[Content] use the general clamp not the cassette type
Use the Air Bag Mod
[Content] use the cassette type clamp
125. Cassette Type
1) DISABLE
2) ENABLE
Setting
Value