68
No.
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Meaning
If the main shaft motor type is inappropriate, the following errors occur:
The IPM over-current on the main shaft board will be cut off.
The motor over-current and connector errors occur.
The motor overload occurs.
When there is no encoder RST signal, an error occurs.
When the encoder RST's upward direction and the AB direction mismatch,
When the position detecting sensor is touched while the machine power is on,
When the position detecting sensor is removed while the machine power is on,
When the revolving magnet and the fixed current coil mismatch in their direction,
the ROM access error occurs.
The motor type communication error occurs.
When the bobbin stitch counter is reset according to the number of stitches,
the error in zoom-in/zoom-out occurs.
The P-shaft motor error occurs.
When the machine body is separated from the table while the power is on, an error occurs.
When the P-shaft motor origin signal is detected, an error occurs.
When the FAN signal does not operate, an error occurs.
When there is abnormality in AC power, an error occurs.
Over-current error
Low-voltage error
CAN communication with extended board error
Not used
Not used
Main board reception error
Main board transmission error
Error in case of the connection P/U during power on
Error in case of the connection P/U during power on
Main shaft synchro error
Not used
Main shaft overload error
No USB inserted error
Upper shaft rocking motor movement error
Lower shaft rocking motor movement error
Upper shaft rocking motor origin motion error
Lower shaft rocking motor origin motion error
Message
Main Motor Err!\nDismatch!\n999!
Over Current\nOver tem\n133!
Over Current\nAbnormal\n131!
Over Load Err!\n129!
EncoderRST Err!\n128!
Encoder AB Err!\n127!
Synchro!\nCon.Inserted!\n60!
Synchro!\nCon.Pulled Out!\n61!
Reverse!\nComm. Error!\n126!
EEPROM!\nAccess error!\nEEPR!
Ser.Com.Err!\nMotor Info Err!
Bobbin Stitch!\Reset Counter
Enlargement!\Reduction \ Err!
P Motor Err\nPush Power S/W!
M/C Open Err\nPush Power S/W!
P Motor Err\nOrg Check Err!\nPower Off!
FAN Error!\nPush Power S/W!
AC Check Err!\nPush Power S/W!
Over Voltage Err!\nPush Power S/W!
Under Voltage Err!\nPush Power S/W!
CAN.Com Err!\Check EXT. I/O BD!\Push Power S/W!
Main Motor\RX Com Err!
Main Motor\TX Com Err!
Main Motor\Exter P/U Con Err!\26
Main Motor\Built P/U Con Err!\27
Main Motor\Synchro Err!\130
Main Motor\Rate Over Err!\200
USB Not Found\Push ESC Key
Head Moter Err\Push Power S/W
Bottom Motor Err\Push Power S/W
Head Motor\Origin Error
Bottom Motor\Origin Error
Err List
Err 41
Err 42
Err 43
Err 44
Err 45
Err 46
Err 47
Err 48
Err 49
Err 50
Err 51
Err 52
Err 53
Err 54
Err 55
Err 56
Err 57
Err 58
Err 59
Err 60
Err 61
Err 62
Err 63
Err 64
Err 65
Err 66
Err 67
Err 68
Err 69
Err 70
Err 71
Err 72
Err 73
Err 74
Err 75
Summary of Contents for SPS/E-5050 Series