70
Occurs while trying to insert USB disk and save
Occurs while trying to insert USB disk and load
Occurs when no USB Disk inserted
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
4
5
6
7
8
9
▷
Alarm Code - [01][XXXX] (Design & Update file Error)
USB Disk has no pattern data
USB Disk has faulty pattern data
USB Disk has no update file
USB Disk has faulty update file
USB Disk has no Para.dat file
USB Disk has faulty Para.dat file
No USB inserted
Wrong format method for USB
Faulty USB connection cable
Check pattern data (001~999)
Check pattern data (001~999)
Check update file (pattern1.exe)
Check update file (pattern1.exe)
Check Para.dat file
Check Para.dat file
Check USB insertion status
Check format method (FAT, FAT32)
Check cable connection status
1
2
3
4
5
6
7
8
9
Cause
Solution
Occurs while trying to make power supply turn on
Occurs while trying to operate the motor
○
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
4
5
▷
Alarm Code - [02][XXXX] (Main Motor Error)
Faulty motor type
Faulty motor connection communication cable
Faulty cable for motor connecting
Faulty main shaft motor board
Faulty main shaft motor connection cable
Check motor type and change
Check cable status and change
Check board and change
Check cable status and change
1
2
3
4
5
Cause
Solution