71
Occurs while trying to make power supply turn on
Occurs while operating motor
Occurs while trying to operate or stop the motor
○
○
○
○
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
4
5
6
7
▷
Alarm Code - [03][XXXX] (XY Motor Error)
Faulty motor
Faulty Amp
Faulty connection cable
Out of sewing scope
Faulty sensor detection
Stoppage by the stop switch
Stoppage due to thread breakage
Change the motor
Change the amp
Check and change the amp parameter
Check cable status and change
Check and modify patter design size through the SSP5.0
Check faulty X,Y sensor and change
Check faulty sensor cable and change
Lift the stop switch
Check thread status and change
1
2
3
4
5
6
7
Cause
Solution
Occurs while trying to make power supply turn on
Occurs while operating motor
Occurs while trying to operate or stop the motor
○
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
4
▷
Alarm Code - [04][XXXX] (Hook Motor Error)
Faulty motor
Faulty Amp
Faulty connection cable
Faulty sensor detection
Change the motor
Change the amp
Check and change the amp parameter
Check cable status and change
Check faulty origin sensor and change
Check faulty sensor cable and change
1
2
3
4
Cause
Solution
Summary of Contents for SPS/E-5050 Series