74
Occurs while trying to make power supply turn on
Occurs while stitching
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
▷
Alarm Code - [09][XXXX] (Voltage Error)
Faulty AC power
Faulty overvoltage
Faulty low-voltage
Check voltage lever and supply power
1
2
3
Cause
Solution
Occurs while trying to make power supply turn on
Occurs while stitching
○
○
○
○
○
Situation when the alarm issues
Appropriate cause
1
2
3
4
5
▷
Alarm Code - [0A][XXXX] (Serial Com. & Can Com. Error)
Faulty motor
Motor communication cable abnormality
Cable abnormality on the motor UVW
Main board communication cable abnormality
CAN initialization error
Check motor specification and change
Check cable status and change
Change operating program
Change CPU board
1
2
3
4
5
Cause
Solution
Summary of Contents for SPS/E-5050 Series