Stability
The temperature of the liquid transported should not 35°C in permanent operation.
The transport of aggressive fluids (acids, bases, etc.) as well as of abrasive substances (e. g. sand)
must be avoided.
Electrical connection
The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse
protection at least 10 A.
The engine is protected from overloading or blocking by means of a built-in motor protection.
In case of overheating the pump is turned off automatically due to the overheat protection and
after cooling down, the pump is automatically started.
Power connection
The pond pump is equipped with a safety plug. The device is designed for connection to an isolated
ground receptacle with 230 V ~ 50 Hz. Make sure that the socket outlet is sufficiently fused (at least
6 A) and safe. Insert the plug in the socket outlet and the pond pump is ready for use.
Installation
REMARK
:
1.
The pump has to be installed under water. Make sure that moisture or water never reaches
the mains connection.
2.
Please make sure, that the line voltage (V) and frequency (Hz) of your electrical circuit agree
with the data on the model plate. They have to be the same.
3.
Do not place the pump on the pond floor directly. Place it on a stone, so it will not suck in the
pond mud.
4.
The pump has to be installed as follows: in a fixed position with fixed or flexible hose.
5.
Comply with the maximum permitted immersion depth (this information is to be found as well
on the model plate).
6.
ATTENTION: Adjust the tightness of cover to change the fountain style. The flow can be
handled by the three way valve.
7.
Connect the pump to the electrical circuit. The pump will start working.
8.
The pump shall work until disconnected from the electrical circuit.
© by WilTec Wildanger Technik GmbH
Item 50328–50336
Page 4