Lock/unlock function

With the correct gear, you need to press “down” until the buzzer sounds twice. The pump is
now locked. To unlock proceed in the same way.

Automatic memory function

When the controller power is cut off suddenly, it still keeps its memory. The pump will auto-
matic recover its operation state as before when the power is switched on another time.

Alarm function

The pump will cut off power immediately and automatically if the pump idles. It will re-start
automatically to work again after 5 s. If still idling, the pump will automatically cut the power off
again. After five times of repeated activation, the pump will power off until re-connect the
power. Meanwhile, the alarm buzzer will sound.

The pump will cut off power automatically and immediately if the impeller is blocked, and the
alarm buzzer will sound until the pump is re-connected to the power supply.

Code definition and troubleshooting

Code

Definition

Status

Solution

P000

Power

Normal

SP00

Gear

Normal

FEE0

Delayed start

Normal

ER05

Short-circuit current display

Abnormal

Check controller unit.

ER04

overheat flicker

Abnormal

Clean pump.

ER03

Pump works without water

Abnormal

Check the pump if working without wa-

ter.

ER02

Pump block

Abnormal

Check the impeller if blocked.

ER01

Over-/undervoltage display

Abnormal

Check voltage.

© by WilTec Wildanger Technik GmbH 

Item 50982, 51192

Page 6 

http://www.WilTec.de
http://www.aoyue.eu

 

03 2021

-1

http://www.teichtip.de

Summary of Contents for 50982

Page 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Page 2: ...ages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pic...

Page 3: ...ransport any liquids other than water Attention The pump will automatically stop working if overloaded or running without water The controller is not water proof put it in a dry and well ventilated pl...

Page 4: ...ectrical circuit with the data on the model plate these data must correspond 3 Connect the pipeline if needed Attention The piping system must not contain bubbles Hose connection diagram is as follows...

Page 5: ...supply Gear level Power W Flow rate h Max lift ing head m 50982 CET 8000 220 240 V 50 Hz SP01 18 3500 1 6 SP02 23 4000 1 9 SP03 28 4600 2 3 SP04 35 5000 2 7 SP05 42 5400 0 1 SP06 51 5800 3 5 SP07 60 6...

Page 6: ...n the pump will power off until re connect the power Meanwhile the alarm buzzer will sound The pump will cut off power automatically and immediately if the impeller is blocked and the alarm buzzer wil...

Page 7: ...er in the pump should be discharged immediately in order to prevent a freezing damage Troubleshooting Problem Cause Solution Pump does not run No power supply Connect the power Burning machine Change...

Page 8: ...e 9 Motor with cable 3 Outlet 10 Rear cover 4 Seal circle 11 Handle 5 Impeller cover 12 Rubber foot 6 Rotor set 13 Gear box with cable 7 O Ring by WilTec Wildanger Technik GmbH Item 50982 51192 Page 8...

Page 9: ...out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correc...

Reviews: