Maintenance/cleaning

Please clean the filter casing, impeller, rotor and shaft part regularly. Please cut off the power before
you clean it.

1. Turn and take off the filter casing (Fig 1, Fig 2).
2. Press the security clasp vertically (Fig 3), and take off the impeller cover (Fig 4).
3. Take off the rotor set (Fig 5), then you can clean or change.
4. Installation position of the O-ring as shown on Fig 6.

If the pump is not used for a long time, please run the pump in clean water for a short time. Then rinse
it with clean water. After that, dry it and keep it in a secure place.

If the temperature is below 0 

, the water in the pump should be discharged immediately in order to

prevent a freezing damage.

Troubleshooting

Problem

Cause

Solution

Pump does not run

No power supply

Connect the power

Burning machine

Change pump

Impeller stall

Clean and re-link to power

Runs without water

Fill with water and re-link to power

Not connected with the controller unit

Re-link to the controller unit

The controller is damaged

Change the controller

Pump noise

Dirt inside

Clean pump 

Shaft break or wear

Change shaft

Pump   water   short-
age

Damage of the impeller

Change impeller

Inlet or outlet obstruction

Clean inlet and outlet

Filter case obstruction 

Clean filter case

Low voltage

Adjust voltage

© by WilTec Wildanger Technik GmbH 

Item 50982, 51192

Page 7 

http://www.WilTec.de
http://www.aoyue.eu

 

03 2021

-1

http://www.teichtip.de

Summary of Contents for 50982

Page 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Page 2: ...ages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pic...

Page 3: ...ransport any liquids other than water Attention The pump will automatically stop working if overloaded or running without water The controller is not water proof put it in a dry and well ventilated pl...

Page 4: ...ectrical circuit with the data on the model plate these data must correspond 3 Connect the pipeline if needed Attention The piping system must not contain bubbles Hose connection diagram is as follows...

Page 5: ...supply Gear level Power W Flow rate h Max lift ing head m 50982 CET 8000 220 240 V 50 Hz SP01 18 3500 1 6 SP02 23 4000 1 9 SP03 28 4600 2 3 SP04 35 5000 2 7 SP05 42 5400 0 1 SP06 51 5800 3 5 SP07 60 6...

Page 6: ...n the pump will power off until re connect the power Meanwhile the alarm buzzer will sound The pump will cut off power automatically and immediately if the impeller is blocked and the alarm buzzer wil...

Page 7: ...er in the pump should be discharged immediately in order to prevent a freezing damage Troubleshooting Problem Cause Solution Pump does not run No power supply Connect the power Burning machine Change...

Page 8: ...e 9 Motor with cable 3 Outlet 10 Rear cover 4 Seal circle 11 Handle 5 Impeller cover 12 Rubber foot 6 Rotor set 13 Gear box with cable 7 O Ring by WilTec Wildanger Technik GmbH Item 50982 51192 Page 8...

Page 9: ...out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correc...

Reviews: