ECCO SG04LP1 | User Manual
35
What this page displays:
Total solar power produced.
MPPT 1 power/voltage/current.
MPPT 2 power/voltage/current.
Grid power.
Grid frequency.
Grid voltage.
Grid current.
Inverter power.
Inverter frequency.
Inverter voltage.
Inverter current.
Load power.
Load voltage.
Battery power charge/discharge.
Battery SOC.
Battery voltage.
Battery current.
Battery temperature.
Solar Column:
Shows total PV (Solar) power at the top and then details of each of the two MPPT’s below L1
& L2 voltage.
Grid Column:
Shows grid total power, frequency, voltage, and current. When selling power to the grid,
the power is negative. When consuming from the grid, the power is positive. If the sign of the grid and HM
(home) powers are not the same when the PV is disconnected and the inverter is only taking energy from
the grid and using the CT connected to Limit-2, then please reverse the polarity of the CT coil. Important: See
Section 4.6 (‘Connecting the CT coil’).
Inverter Column:
Showing inverter total power, frequency, L1, L2, voltage, current, and power.
Load Column:
Showing total load power, load voltage, and power on L1 and L2.
Battery Column:
Shows total power from the battery, battery SOC, battery voltage, battery current (negative
means charge, positive means discharge) battery temperature (shows zero if the battery temperature sensor
is not connected). DC transformer temperature and AC heatsink temperature (When the temperature reach
-
es 90°C, it will display in red, and the performance of the inverter will start deteriorating when it reaches
110°C. Subsequently, the inverter will shut down to allow it to cool and reduce its temperature.
5.5. System Flow Page
Access by clicking on the bar chart on the
Home Page.
To better understand the functioning of
your system, take a look at the figure at
right:
1. The PV modules charge the batteries.
2.
When the batteries reach a specific level
(programmable), the battery power is
fed into the inverter.
3. The inverter can then supply power to
the grid (export or no export), load, and
auxiliary or smart load.
4. CT coil controls the export power.
Summary of Contents for ECCO SUN-3.6K-SG05LP1-EU
Page 9: ...ECCO SG04LP1 User Manual 9 2 1 Product Size ...
Page 17: ...ECCO SG04LP1 User Manual 17 4 5 Function Port Definition ...
Page 21: ...ECCO SG04LP1 User Manual 21 ...
Page 23: ...ECCO SG04LP1 User Manual 23 4 9 1 Recommended AC Surge Protector ...
Page 26: ...ECCO SG04LP1 User Manual 26 4 12 Meter Connection 4 12 1 System Connection for the CHNT Meter ...
Page 27: ...ECCO SG04LP1 User Manual 27 4 13 Wiring System for Inverter ...
Page 30: ...ECCO SG04LP1 User Manual 30 4 16 Single Phase Parallel Connection Diagram 03 02 01 ...
Page 31: ...ECCO SG04LP1 User Manual 31 4 17 Three Phase Parallel Inverter 03 02 01 ...
Page 32: ...ECCO SG04LP1 User Manual 32 4 18 Typical Application Diagram of Diesel Generator ...
Page 63: ...ECCO SG04LP1 User Manual 63 6 OPERATING MODES 6 1 Mode I Basic 6 2 Mode II With Generator ...
Page 64: ...ECCO SG04LP1 User Manual 64 6 3 Mode III With Smart Load 6 4 Mode IV AC Couple ...
Page 65: ...ECCO SG04LP1 User Manual 65 ...
Page 71: ...Ltd wered by Po ...