Dump Load or Diversion Load is an important part of an off-grid power system. When the battery ( Battery
Bank ) is fully charged, and the water turbine / wind turbine / solar PV module is still generating, a dump load
is a useful device to send spare electricity to. This can be done by using a switch on a smart load option or by
utilising a wind turbine controller with a built-in dump load. Also, a hot water tank controlled via a smart-load
can act as a good ‘dump-load’ however, in very windy conditions it may be necessary to shunt the output.
Most wind turbines are three-phase PM type. Therefore, either a wind turbine controller or a direct connec
-
tion to the MPPT via a simple protection circuit will be required.
5.21. Advanced Settings for Auxiliary Load
To configure Auxiliary Load (previously known as “smart load”) settings, click on the AUX LOAD icon.
What this page displays:
Use of the Gen (Aux) input or output.
What you can do from this page:
Set up a generator input.
Set up an auxiliary (smart) load.
Set up Peak Power Shaving.
Use an additional inverter or micro inverter.
A nice feature of this page is that when the batteries are full and the inverter is still producing power from
the solar PV or turbine, it is possible to direct the power generated to another load such as a water heater.
Summary of Contents for ECCO SUN-3.6K-SG05LP1-EU
Page 9: ...ECCO SG04LP1 User Manual 9 2 1 Product Size ...
Page 17: ...ECCO SG04LP1 User Manual 17 4 5 Function Port Definition ...
Page 21: ...ECCO SG04LP1 User Manual 21 ...
Page 23: ...ECCO SG04LP1 User Manual 23 4 9 1 Recommended AC Surge Protector ...
Page 26: ...ECCO SG04LP1 User Manual 26 4 12 Meter Connection 4 12 1 System Connection for the CHNT Meter ...
Page 27: ...ECCO SG04LP1 User Manual 27 4 13 Wiring System for Inverter ...
Page 30: ...ECCO SG04LP1 User Manual 30 4 16 Single Phase Parallel Connection Diagram 03 02 01 ...
Page 31: ...ECCO SG04LP1 User Manual 31 4 17 Three Phase Parallel Inverter 03 02 01 ...
Page 32: ...ECCO SG04LP1 User Manual 32 4 18 Typical Application Diagram of Diesel Generator ...
Page 63: ...ECCO SG04LP1 User Manual 63 6 OPERATING MODES 6 1 Mode I Basic 6 2 Mode II With Generator ...
Page 64: ...ECCO SG04LP1 User Manual 64 6 3 Mode III With Smart Load 6 4 Mode IV AC Couple ...
Page 65: ...ECCO SG04LP1 User Manual 65 ...
Page 71: ...Ltd wered by Po ...