4.6.1. PV Module Selection
When selecting proper PV modules, please be sure to consider below parameters:
1. Open circuit Voltage (Voc) of PV modules can not exceed max. PV array open circuit voltage
of inverter.
2. Open circuit Voltage (Voc) of PV modules should be higher than min. start voltage.
3. The PV modules used to connected to this inverter shall be Class A rating certified accord-
ing to lEC 61730.
Inverter Model
25kW
30kW
40kW
50kW
PV Input Voltage
600V (180V~1000V)
PV Array MPPT Voltage Range
150V-850V
No. of MPP Trackers
2
3
4
No. of Strings per MPP Tracker
2+2
2+2+2
2+2+2+2
4.6.2. PV Module Wiring
1. Switch the Grid Supply Main Switch (AC) OFF.
2. Switch the DC isolator OFF.
3. Assemble PV input connector to the inverter.
Before connection, please ensure the polarity of the output voltage of PV array
matched the DC+ and DC- symbols.
Please do not connect the PV array positive and negative pole to the gound. This
can seriously damage the inverter.
Before connecting the inverter, please make sure the PV array open-circuit voltage
is within the maximum limit of the inverter.
Summary of Contents for SUN-25K-SG01HP3-EU-BM2
Page 19: ...Page 19 Hybrid Inverter Installer Manual 4 4 1 Function Ports Definition ...
Page 26: ...Page 26 Hybrid Inverter Installer Manual ...
Page 27: ...Page 27 Hybrid Inverter Installer Manual ...
Page 29: ...Page 29 Hybrid Inverter Installer Manual 4 10 Wiring System for Inverter ...
Page 30: ...Page 30 Hybrid Inverter Installer Manual 4 11 Wiring Diagram ...
Page 31: ...Page 31 Hybrid Inverter Installer Manual ...
Page 32: ...Page 32 Hybrid Inverter Installer Manual 4 12 Typical Application Diagram of Diesel Generator ...