4.8. Earth Connection (MANDATORY)
Ground cable shall be connected to ground plate on grid side this prevents electric shock if the
original protective conductor fails.
When the inverter is in the off-grid state, the N line needs to be connected to the
earth.
In final installation,breaker certified according to IEC 60947-1 and IEC 60947-2 shall
be installed with the equipment.