Page | 54
Hybrid Inverter | Installer Manual
Example
:
This example shows the battery being charged up to 100% by both the Grid and Solar PV from
8 a.m. to 11 a.m. and then being able to supply up to 4kW of battery-power to the ‘essential’
loads from the ‘Load’ Port until the battery SOC drops to 50%.
IMPORTANT
- When charging the batteries from the Grid or Generator, please ensure you have
set the correct correct battery-charging settings on the battery charge as shown in Section
4.10 ‘Battery Setup’ Home Page. If the ‘Use Timer’ function is activated then the inverter will
use the battery power according to your settings when the Grid is present. If this function is not
set, the batteries WILL ONLY be used for backup when there is no utility grid power.
Example
:
This is a zero-export power to the grid example.
The power produced is supplying the ‘Non-Essential Load’ while the inverter is set at a max-
imum power of 8kW (Max Sell Power). The inverter is connected to the grid, but no export is
performed. The unit allows small amounts of power to flow from the Grid (100W Zero Export
Power) to prevent any back-flow. In this example, the solar PV is prioritised to supply the Load
first and then subsequently, charge the battery.
Summary of Contents for SUN-25K-SG01HP3-EU-BM2
Page 19: ...Page 19 Hybrid Inverter Installer Manual 4 4 1 Function Ports Definition ...
Page 26: ...Page 26 Hybrid Inverter Installer Manual ...
Page 27: ...Page 27 Hybrid Inverter Installer Manual ...
Page 29: ...Page 29 Hybrid Inverter Installer Manual 4 10 Wiring System for Inverter ...
Page 30: ...Page 30 Hybrid Inverter Installer Manual 4 11 Wiring Diagram ...
Page 31: ...Page 31 Hybrid Inverter Installer Manual ...
Page 32: ...Page 32 Hybrid Inverter Installer Manual 4 12 Typical Application Diagram of Diesel Generator ...