Page | 60
Hybrid Inverter | Installer Manual
Voltage (V)
Max. Current (A)
Power (W)
150
23.33
3500
200
17.50
3500
250
14.00
3500
300
11.67
3500
400
8.75
3500
5.19. Advanced Settings for Wind Turbines
To configure wind turbine settings, click on the ADVANCE icon.
What this page displays:
If one or both of the MPPTs are connected to a wind turbine.
What you can do from this page:
Select the MPPT to be used as a turbine input.
The table below shows the maximum current depending on the voltage of the wind turbine.
DO NOT use a wind turbine that exceeds 400V.
Use a self-breaking wind turbine. Once the batteries are fully charged and the
inverter is not exporting any power the load can drop. This can cause the tur-
bine to speed up dramatically, which can be very dangerous and usually hap-
pens suddenly. Thus, it is essential to use a self-breaking turbine.