Page | 62
Hybrid Inverter | Installer Manual
Aux Load off Battery %
or Voltage
Battery level when the Aux load switches off
Aux Load on Battery %
or Voltage
Battery level when the Aux load switches on.
Solar Power
Power limiter to the maximum power allowed to the Aux load.
Gen Input
Tick this box if using a Generator.
Aux Load Output
Tick this box if using an Aux or Smart Load.
For Micro inverter Input
Tick this box if intending to connect a supplementary inverter or
micro inverter (Max. 4kW).
Zero Export
Tick this box to stop exporting power produced by the Aux Load.
Gen Peak Shaving
Tick this box to use peak power shaving.
5.21. Advanced Settings for Peak Shaving
To configure Peak Power Shaving function, click on the AUX LOAD icon.icon.
What this page displays:
Generator peak shaving is ON or OFF.
Peak Power Shaving value.
What you can do from this page:
Switch on the generator and/or grid
peak power saving and set the power
shaving value.
Peak Shaving:
This is a technique used to reduce electrical power consumption during periods
of maximum demand on the utility grid. This enables the user to save substantial amounts of
money due to the expensive peak power charges.
Summary of Contents for SUN-25K-SG01HP3-EU-BM2
Page 19: ...Page 19 Hybrid Inverter Installer Manual 4 4 1 Function Ports Definition ...
Page 26: ...Page 26 Hybrid Inverter Installer Manual ...
Page 27: ...Page 27 Hybrid Inverter Installer Manual ...
Page 29: ...Page 29 Hybrid Inverter Installer Manual 4 10 Wiring System for Inverter ...
Page 30: ...Page 30 Hybrid Inverter Installer Manual 4 11 Wiring Diagram ...
Page 31: ...Page 31 Hybrid Inverter Installer Manual ...
Page 32: ...Page 32 Hybrid Inverter Installer Manual 4 12 Typical Application Diagram of Diesel Generator ...