ignited automatically.
The controller uses another method of
intermediate cleaning, in which the fire
is not extinguished, but only increases
the power of the fan or triggers the FC
output for some mechanical cleaning
mechanism.
The required settings of this cleaning
method are made from the menu
"Service settings" -> "Combustion
settings" -> "Fuel X" -> "Intermediate
cleaning"
. The parameters to be set are:
the time during which the intermediate
cleaning procedure is repeated, the fan
speed to be maintained during cleaning,
how long to clean and whether to use
the FC output. The pellet supply is not
interrupted during this cleaning method.
9.4. Burner operation:
9.4.1. Switching the burner on / off.
Select Mode
OFF
ON
OFF
Timers
With the
On / Off button
goes to the
mode selection menu.
Use the or buttons
or
to highlight
higher or lower row. There is a choice
between three operating modes: Off,
On and Timers. The next time you press
the On / Off button. switches to the
highlighted mode. If no button is pressed
for more than 5 seconds or
- is
pressed, it will exit without changing
mode or condition. To make sure that the
burner is switched off after selecting the
Off mode, you must make sure that the
bottom line does not appear in green,
with some of the operating phases of the
burner given in the following table.
Working phase
1
Cleaning
6
Power Р1
2
Charging
7
Power Р2
3
ignition
8
Power Р3
4
Heating
9
Intermediate
cleaning
5
Maintenance
10
Extinguishing
When the burner is in "Off" mode, it will
not work. If the burner was lit during the
switch to this mode, a fire extinguishing
procedure will be performed.
Complete fire extinguishing and cleaning
require some time. It is normal for the
burner and boiler units to continue to
operate even after switching to "Off"
mode.
Circulation pumps can continue to
operate despite the burner being
switched off as long as the conditions for
their operation are met. In this way the