27
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
Message
Clear
грешка
Description
1
Reverse combustion
button
A reverse combustion thermostat has tripped
2
Interrupted TS boiler
automatically
Interrupted boiler thermal sensor
3
Short in TS boiler
automatically
Short in the boiler thermal sensor
4
Frozen boiler
button
Time and date of registration of the damage
5
Ignition failure
button
6
Interrupted TC RB
automatically
Interrupted thermal combustion sensor
7
Short in TS RB
automatically
Short in the thermal combustion sensor
8
Interrupted TS boiler
automatically
Interrupted thermal sensor of the DHW boiler
9
Short in ТС бойлер
automatically
Short in the DHW boiler thermal sensor
10
Interrupted TC Pt100
automatically
Interrupted flue gas thermosensor-Pt100
11
Short in ТС Pt100
automatically
Short in flue gas thermosensor-Pt100
12
High temp., Smoke
button
Temperature of flue gas is very high
13
Dangerous temp.,
Smoke
button
Temperature of exhaust gases is unacceptably high
14
Settings menu
---
It is entered in the system settings menus
15
No executable
module
---
No connection to "Executive module"
16
On power supply
---
Time and date of power on
17
Off power supply
---
Time and date of power failure
18
Begining
---
Record restart of the controller
When error messages are displayed in red in the bottom field of the main screen, they
can be cleared in the following ways:
• automatically after the cause has disappeared, leading to their appearance for all
messages with automatic clearing enabled.
• by pressing and holding a button
for more than 2 seconds while the display is in
the main screen and when the cause that led to their appearance disappears
Table 5.