Important recommendations when installing the collector   
- It is very critical to keep the front cover on until the whole circuit is full of thermal fluid 
otherwise very high temperatures may appear on the collectors which can damage them. 
- Verify again that the inclination towards the outlet of about 1-2% exists. The inclination is 
imperative for the air venting of the closed circuit through a venting valve installed at the 
highest point of the system. 
- If more than one is installed, connect the collectors with appropriate joints thermally 
insulated. The distance between them must be kept at the minimum. The system of collectors 
should be connected to the hot water tank (heat exchanger of the tank) with tubing properly 
insulated. When installing collectors in parallel, it is more practical to use the four outlets 
available for the middle ones, connect the lower inlet of the first one on the left to the 
discharge of the circulating pump and on the right close with a cap its upper inlet. Then 
connect the upper outlet of the last one to the heat exchanger of the tank and close the lower 
outlet with a cap. 
A circulation pump with appropriate automatism must be used for the circulation of the 
thermal liquid in the closed circuits. 
Attention must be given so that all collectors have an interrupted slope. 
- Prepare the mixture using the thermal fluid and water - please see the PG label 

Summary of Contents for PK SL AL 2.0

Page 1: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL For SOLAR COLLECTORS SL AL With full plate aluminum absorber model serial number version 01 SRCC 2 2011...

Page 2: ...against lightning 6 6 COLLECTORS INTERCONNECTING IN A FIELD WITH 20m 6 7 Pressure loss 7 8 Recommended angle of installation of the collector 7 9 Collector protection against frost 8 10 Maintenance 8...

Page 3: ...measures to make them compliant regulations and norms concerning safety installation and operation of solar collectors protective gloves eyewear should be used make sure collector is securely attache...

Page 4: ...stallation user CAUTION Danger of injury damage of system due to incompetent operation The solar collector must be serviced only by persons familiar with the operation manual Structural changes to col...

Page 5: ...osiphonic solar systems or as part of forced circulation central system for heating sanitary water space heating air conditioning and pool heating The collectors PK SL AL are flat solar collectors wit...

Page 6: ...sting or earth them to an earth rod using wire of the same size The route of this wire should be always outdoors Ask specialist for more information 6 COLLECTORS INTERCONNECTING IN A FIELD WITH 20m Fo...

Page 7: ...lace plus 5 At this angle the maximum of the year around efficiency is achieved In case of difficulty to follow the above rule try to keep the inclination between 30 and 50 in order to benefit a minim...

Page 8: ...stallation is near electrical wires keep safety distance minimum 5 meters and pay maximum attention when handing long parts of the support structures or tools for the installation 10 2 Selection of in...

Page 9: ...eight of the collectors and other parts that will be installed The installation should be done according to the electric plumbing and town planning regulations applicable in the installation area 11 M...

Page 10: ...e between them must be kept at the minimum The system of collectors should be connected to the hot water tank heat exchanger of the tank with tubing properly insulated When installing collectors in pa...

Page 11: ...ticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after noticing the defect as it is provided for in the general conditions of sale 14 2...

Page 12: ...ether the claim has grounds or not and whether the defect is within the scope of the warranty set forth in this certificate for limited warranty after which informs the customer as to its decision 14...

Page 13: ...aterial of solar glass K Heat tempered prismatic glass Material of pipes F Copper Absorber pipes pcs diameter G 9 x 8 11 x 8 Manifold pipes pcs diameter 2 x 22 Inlet Outlet P N 22 Material of absorber...

Page 14: ...l protection regulation 16 2 RECYCLING AND WASTE DISPOSAL At the end of life cycle of each product its components are due to be disposed of in conformity with regulatory prescriptions According to Dir...

Page 15: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 15 EN Notes...

Page 16: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 16 EN...

Reviews: