background image

ELECTRIC FLAT PANEL FIREPLACE HEATER 

Model#:       STFP 40       STFP 50       STFP 60     SF-BG72     STFP 100 

 

OWNER’S MANUAL – RIVA  SERIES 

 

 

40”/50"/60"/72”/100” Wall Mounted / Built-in 

Electric Fireplace

 

 

 

AC 120V 60Hz 1500W 

 

Read and understand

 this entire owner's manual, including 

all safety 

information

, before

 plugging in

 or

 using

 this product. Failure to do so 

could result in 

fire, electric shock, or serious personal injury.

WARNING

Keep this owner's manual

 for future reference.  If you sell or give this 

product away, 

make sure this manual accompanies this product

CAUTION

 www.sunteck.ca

info@sunteck.ca 

Summary of Contents for RIVA 100

Page 1: ...INSTALLATION MANUAL RO RIVA...

Page 2: ...500W Read and understand this entire owner s manual including all safety information before plugging in or using this product Failure to do so could result in re electric shock or serious personal inj...

Page 3: ...sparking parts inside DO NOT use it in areas where gasoline paint or ammable liquids are used or stored Use this heater only as described in this manual Any other use not recommended by the manufactu...

Page 4: ...use immediately and have a quali ed electrician inspect and or replace the faulty outlets The power cord supplied with the heater has three prongs two at blades live and neutral and one round pin grou...

Page 5: ...85 119cm 20 51 52 1cm 12 30 5cm 45 28 115cm RIVA 60 60 152 4cm 21 46 54 4cm 5 51 14cm 46 85 119cm 20 51 52 1cm 12 30 5cm 45 28 115cm RIVA 72 72 182 8cm 21 46 54 4cm 5 51 14cm 68 39 173 72cm 20 51 52 1...

Page 6: ...USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION Your appliance is a wall mounted recessed and or mantel installed appliance Select a s...

Page 7: ...52 71CM RIVA 60 47 119 38CM 20 75 52 71CM RIVA 60 47 119 38CM 20 75 52 71CM RIVA 72 69 175 26CM 20 75 52 71CM RIVA 100 97 246 38 CM 20 75 52 71CM STEP B Fix the three wall anchors in each side of the...

Page 8: ...appliance is fully recessed into the wall Use the 6 screws provided to lock the appliance into the wall with the existing two side anges see Figure E Install the media and re install the glass front...

Page 9: ...to Figure 1 D Mark out location then mount the bracket s onto the wall using the supplied screws This bracket MUST have the hooks facing upward and be level NOTE It is strongly recommended that the mo...

Page 10: ...if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States A Remove the cover p...

Page 11: ...selected A Glass front must be removed and the appliance must be mounted in its final location before the log set crystal pebble embers are installed B If your replace come with log set remove the log...

Page 12: ...FORMATION on Pages 2 and 3 Make sure the outlet is in good condition and that the plug is not loose NEVER exceed the maximum amperage for the circuit DO NOT plug other appliances into the same circuit...

Page 13: ...ontrol Turns o ame e ect 1 Press once Indicator light turns on Power turns on All functions enabled 2 Press again Flame e ect turns o Unit goes to standby All functions turn o TEMP 1 Press once Touch...

Page 14: ...ater turns on and after the heater turns o 1 Press once Indicator lights up Fan blows cool air for 10 seconds 750W heater turns on and blows warm air 2 Press again Indicator lights up 1500W heater tur...

Page 15: ...onto the cloth or towel Dry thoroughly with a paper towel or lint free cloth NEVER use abrasive cleansers liquid sprays or any cleaner that could scratch the surface Vents Use a vacuum or duster to re...

Page 16: ...www sunteck ca info sunteck ca...