The bathroom heating panel is designed to heat bathrooms and dry laundry. The laundry can be dried solely on the 

metal rungs avoiding direct contact with the heating area of the panel. The front side of the heating panel has been 

treated with a surface coating. The surface of the heating panel is smooth or sandblasted depending on the panel 

type. It is a Class I appliance with IP 44 powered with 230V/50Hz

The product is designed to be installed on a wall and is equipped with a thermostat to prevent overheating. Plugging 

into the electrical mains is done by means of a coiled connecting cable ended with a sheathed male plug UNISCHUKO 

with a circuit closer (type V) or with a special male plug UNISCHUKO with an integrated knob controlling space 

temperature, wih a circuit closer and a signal diode (type R). The heating panel may be installed on surfaces with  

Class A1, A2, B, C or D fire resistance rating. The dimensions and input power of the models are listed in the table 

below.

PRODUCT DESCRIPTION

i

A

C

B

D

A

C

B

D

Multigear model is equipped with removable hangers and support leg, which allows standalone use.

TYPE

POWER (W)

A (mm)

B (mm)

C (mm)

D (mm) SUPPORT (mm)

SUNTHERM DRIER 200

200

840

390

750

300

-

SUNTHERM DRIER 400

400

890

530

770

420

-

SUNTHERM DRIER MULTIGEAR

400

890

530

770

420

770

Summary of Contents for DRIER 200

Page 1: ...INFRAROT HEIZPANEEL INFRARED HEATING PANEL SUNTHERM DRIER BEDIENUNGSANLEITUNG seite 2 5 INSTRUCTION MANUAL page 6 9...

Page 2: ...er ts aufgekl rt werden und die m glichen Gefahren verstehen Kinder d rfen nicht mit dem Ger t spielen Die durch den Benutzer durchzuf hrende Reinigung und Wartung d rfen nicht unbeaufsichtigte Kinder...

Page 3: ...Produkt wird mit berhitzungsschutz und Montagematerial f r die Wand geliefert Der Anschluss erfolgt ber das Anschlusskabel mit Schukostecker Ein Ausschlater V oder Raumthermostat R Das Heizpaneel kan...

Page 4: ...ellung der Temperaturwahlscheibe geregelt Die Beendigung der T tigkeit des Ger ts erfolgt durch Ausschalten des Schalters Trocknungsprogramm Der Regler wird zun chst mit dem Schalter in den Heizmodus...

Page 5: ...g von der Umgebung im beheizten Raum kann sich der Farbton der Strahlungsfl che des Heizpaneels ver ndern S mtliche Reparaturen d rfen nur vom Hersteller vorgenommen werden WARTUNG UND BETRIEB F r die...

Page 6: ...ance Cleaning and maintenance carried out by the user must not be undertaken by unsupervised children If the power connection is damaged it must be replaced by the manufacturer the manufacturer s serv...

Page 7: ...al mains is done by means of a coiled connecting cable ended with a sheathed male plug UNISCHUKO with a circuit closer type V or with a special male plug UNISCHUKO with an integrated knob controlling...

Page 8: ...tivation of the drying programme he she must press the button which activates the drying programme The orange indicator light will light up and the electric heating element will work at full power for...

Page 9: ...he heating panel must be cold and disconnected from the power source during maintenance During the first operation of the heating panel or the first operation in a given heating season heat the panel...

Page 10: ...office suntherm austria at www suntherm at MADE IN EU Compliant...

Reviews: