8
The heating panels are designed to be mounted on the wall at a distance of at least 0.2m from the corner. There
must be at least 0.5 m of unobstructed air space in front of the heating panel to ensure free circulation of air
and to prevent overheating of the unit. In bathrooms, the heating panel must be installed in conformity with the
regulation IEC 60364-7-701 and must not be placed into the zone marked in the picture on the right. Installation in
the bathroom must ensure that the person in the bath or the shower cannot touch the switch or other controlling
devices.
PLACEMENT
225 mm
60 mm
60 mm
60 mm
The connected heating panel is set into operation by connecting the plug to the 230V/50Hz socket and switching on
the switch marked with the symbol, which is located on the regulator.
The control dial on the regulator is used to set the required temperature in the room. The lowest temperature is set
in the position marked with the small symbol, the highest in the position marked with the large symbol.
Temperature is regulated within the range 5° - 30°C according to the position of the control dial. Operation of the
appliance is ended by switching off the switch.
Drying programme
The regulator is first set into drying mode using the switch. If the user requires activation of the drying
programme, he/she must press the button, which activates the drying programme. The orange indicator light will
light up and the electric heating element will work at full power for a period of two hours. After this period has ended,
the regulator will switch back to heating mode. If the user wishes to end the drying programme earlier, pressing
the button again ends the drying programme and the regulator will switch to heating mode.
Operational indication – indicator light status
Green
- the equipment is switched on, it is not heating, the temperature in the room is higher than the temperature
set on the regulator.
Red
- the equipment is in operation, heating in heating mode.
Orange
- the equipment is in operation, heating in drying mode.
Unlit
- the regulator is switched off.
Flashing (2-5 red flashes once every minute)
– error status. The manufacturer recommends switching off the
equipment for a period of 1 minute and then restarting. If the equipment does not start up, a service
technician must be called in.
THERMOSTAT OPERATION (VARIANT R)
The panel has a 15-year functional warranty from the date of sale. The warranty does not apply to defects caused
by transport, inappropriate storage, unauthorized installation or any interference to the product structure. The
warranty also does not cover usual wear and tear of the panel or partial changes to the colour of the panel radiant
surface. The purchase receipt serves as the warranty certificate.