15th
Data Format (Default: 8N1)
This setting determines the format of the data on the serial port.The
default is 8 data bits, No parity, and 1 Stop bit.
7.2.4. RS2 Configuration
This setting determines which protocol the serial server will use to transmit serial port data over the TDD-COFDM
network.
Remote IP Address
IP address of distant device to which UDP packets are sent when data
received at serial port.
Default:
192.168.55.2(master)
192.168.55.1(slave)
Remote Port
UDP port of distant device mentioned above.
Default:
20002
Listening Port
UDP port which the IP Series listens to (monitors).
UDP packets received on this port are forwarded to the unit’s serial
port.
Default:
20002
UDP Timeout(s)
UDP Timeout in second.
Default:
10
Character Timeout(ms)
Character Timeout in millisecond.
Default:10
Max Packet size
Default:1024
7.2.5. IP New Network Configuration
This setting helps you to change the IP address of devices. The default of master’s IP address is
192.168.55.1.
The
default of slave’s IP address is
192.168.55.2