5 of 32
© 2015 Watts Water Technologies
Installation must be performed by qualified personnel, in accordance with local codes and
standards. A licensed electrician is recommended.
Phase 1 - Preparations
ALWAYS
pay close attention to voltage and amperage requirements of the breaker, the
thermostat, and the TapeMat. For instance, do not supply 240 VAC power to 120
VAC TapeMat as damage will result.
ALWAYS
make sure all electrical work is done by qualified persons in accordance with local
building and electrical codes, Section 62 of the Canadian Electrical Code (CEC)
Part I, and the National Electrical Code (NEC), especially Article 424.
ALWAYS
use copper only as supply conductors to the thermostat.
Do not use aluminum.
ALWAYS
seek help if a problem arises. If ever in doubt about the correct installation procedure
to follow, or if the product appears to be damaged, the factory must be called before
proceeding with the installation.
Before installing TapeMat, make sure to fully inspect the products and carefully plan the site.
Items Needed
Materials:
• SunStat thermostat control with floor sensor.
• SunStat Relay control (if required)
• Control electrical box (UL Listed, extra deep, see control instructions for size and type required)
• Junction electric box (if required, see Step 2.2)
• Wire nuts (Must be UL Listed and proper size)
• Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
• 12-gauge or 14-gauge electrical wiring cable (consult local code)
• Nail plate (see Step 3.8)
Tools:
• Digital multi-meter for ohms testing; must read up to 20,000 ohms to measure sensor
• Drill with 1/2" & 3/4" bits
• Hammer and chisel
• Hot glue gun and hot glue (craft grade)
• Wire strippers
• Phillips screwdriver
• Fish tape
• Hole saw
• Floor covering installation tools