background image

21 

Copyright © 2009 Suntrap Pty Ltd All rights reserved ABN 87 117 052 856 

Refund Policy

1. Suntrap products (such as solar collectors, water tanks, pumps, valves etc.) –

In any situation where a product fails to perform as specified, you are entitled to an 
exchange or refund upon return of the product(s) to Suntrap within 30 days of purchase.

2. Labour charges and shipping charges will not be refunded.
3. If you change your mind, Suntrap will not refund any monies after the system has been installed.

due to faulty materials.

Scope of Warranty

10. This warranty does not apply to any defects or damage not due to faulty factory parts, including but 

not limited to defects or damage caused by or resulting from:-

a) Accidental damage, abuse, misuse, maltreatment, abnormal stress or strain, harsh or adverse   

water conditions, contamination or corrosion from particles in the water supply.

b)  Alteration or repair of the Suntrap solar hot water system other than by an approved Suntrap 

licensed installer, the installer with written authorisation from Suntrap, or a Technician from a Gas 
or Electricity utility with approval from Suntrap.

11. This warranty does not cover the effects of the connection of the Suntrap Solar Hot water system to  

bore waters and highly mineralised waters where the water used exceeds the following levels: 
Total dissolved solids 600 mg/litre or p.p.m: Electrical conductivity 850 uS/cm: Total hardness 
200 mg/litre or p.p.m: Chloride 250 mg/litre or p.p.m: Magnesium 10 mg/litre or p.p.m: Sodium 
150 mg/litre or p.p.m: pH Min 6.5 and Max 8.5.

12. This warranty does not cover the effects of sludge/sediment as a result of connection to a water 

supply from unfiltered or mineral content sources i.e. spring, dam, bore, river or other

.

13. Where a Suntrap solar hot water system or a component is replaced by Suntrap, the balance of any 

original warranty will remain effective. The replacement part does not carry any additional 
warranty.

14. Suntrap's obligations under this warranty are limited to repairing or replacing the Suntrap solar hot 

water system or components. To the extent permitted by law, Suntrap will not be liable for any loss 
or damage to roof, furniture, carpets, walls, foundations or any other consequential loss of any kind 
caused by a defect in the Suntrap solar hot water system or any component.

Revised 22

nd

June 2010

Terms and Conditions of Warranty and Refund Policy

THE SUNTRAP SOLAR HOT WATER PRODUCTS THAT YOU HAVE PURCHASED COME WITH A       

COMPREHENSIVE WARRANTY. 

THE TERMS AND CONDITIONS OF THE WARRANTY ARE SET OUT BELOW. 

1. Solar Collectors  

All U tube series solar collectors are covered by a 10 year warranty.

2. Stainless Steel Water Tanks

Stainless steel water tanks are covered by a 10 year manufacturer’s warranty. 

3. Solar Booster Pumps

All solar booster pumps are covered by a 5 year warranty. 

4. Solar Controllers

All solar controllers are covered by a 5 year warranty. 

5. Gas Boost Heaters

All Bosch gas boost heaters are covered by a 5 year manufacturer’s warranty.

6. Valves

All valves are covered by a 5 year warranty.

7. Workmanship 

Workmanship is covered by the installers warranty.

8. This warranty is for normal use of the solar hot water system installed in accordance with the Suntrap 

Solar Hot Water Installation Instructions and Owners Manual, and covers the repair and/or 
replacement of any failed component in the system or where necessary. Under this warranty 
Suntrap will repair or replace the component free of charge. The decision to repair or replace the 
component will be entirely at the discretion of Suntrap.

9. This warranty only applies to defects in the Suntrap solar hot water systems which have arisen solely

Suntrap Pty Ltd
ABN: 87 117 052 856
PO Box 3164
Dural NSW 2158
Tel:  02 9651 2866

Summary of Contents for ST-160-16

Page 1: ...c Boost Models ST 160 16 ST 250 32 ST 315 32 ST 250 48 ST 315 48 December 2010 issue 10 4 Suntrap Pty Ltd PO Box 3164 Dural NSW 2158 Tel 02 9651 2866 Gas Boost Models ST 160NG21 16 ST 160LPG21 16 ST 2...

Page 2: ...s 6 The Suntrap Solar Control Kit 7 Connections to the Suntrap Solar Collectors 8 Connections to the top of the Solar Hot Water Tank 9 Connections to the middle and bottom of the Solar Hot Water Tank...

Page 3: ...ated tube collectors Configuration Annual Energy Saving 10 Year Renewable Energy Certificate Allocation Zone 1 Zone 2 Zone 3 Zone 4 Zone 1 Zone 2 Zone 3 Zone 4 ST 160NG21 16 ST 160LPG21 16 ST 250NG26...

Page 4: ...the pipe between the Solar preheat tank and Gas Booster must use Armaflex 32mm thickness insulation 2 About your Suntrap Solar Hot Water System Congratulations for choosing a Suntrap Solar Hot Water...

Page 5: ...e tray so that in the event of a leak the property will not be damaged by water AS NZS 3500 4 Draining of the safe tray must also comply with AS NZS 3500 4 Caring for your system At the top of the Sol...

Page 6: ...tre solar hot water tank with 2 solar collectors and electric boost 1980mm h x 580mm dia ST 250 48 250 litre solar hot water tank with 3 solar collectors and electric boost 1620mm h x 580mm dia ST 315...

Page 7: ...x 3 4 CTI unions 1 x 82mm x 20mm diameter copper pipe FCS002 Coupling components used to connect 2 x Solar Collectors together For 3 x solar collectors ST 250 48 ST 315 48 ST 250NG26 48 ST 250LPG26 48...

Page 8: ...ples 1 x W62 straight brass fitting Part n PLV00A 1 x Pressure Limiting Valve 500 kpa assembly 1 x 15mm nipple 1 x W62 straight brass fitting Part n NRV00A 1 x Solar Return Inlet check valve 1 x 20mm...

Page 9: ...is item is packed behind the electrical heater accesspanel In the Everlast Electric boosted Solar Tanks END004 Plastic End Caps for Roof Frame SET348 3 x Solar Collectors EST315 Everlast stainless ste...

Page 10: ...SWR00A Solar Collector outlet assembly SWI00A Solar Collector inlet assembly including the Expansion Control Valve NRV00A Solar Return Inlet Non Return Valve with Purge Valve assembly Solar hot water...

Page 11: ...tacle Shut off ball valve S T C Use copper Tee G Cold Water in V Blanking Plug Solar Collector temp receptacle P Solar Hot water tank R Solar Hot Water tank Solar Pump Solar Control Unit Solar Collect...

Page 12: ...are the Tank sensor from Point H and the Collector sensor from Point K cables E 1 2 3 D The Suntrap Solar Control Kit Gas The Gas Boost Solar Control Kit contains the following items 1 The Solar Pump...

Page 13: ...ve and the M x CTI Conetite union to join to 15 mm pipe Point L Part n SCU20A and SOV00A Part n CWI20A H and BSR00A U Part n SWR00A L Part n SWI00A K U H L K 850kpa Pressure and Temperature Relief val...

Page 14: ...hrough the F to 15mm brass adapter use thread tape Screw the Expansion Control Valve onto the Tee using the 15 mm nipple supplied use thread tape The solar collectors are connected in series using bra...

Page 15: ...olar collector threaded connections Note This part is not supplied with a 1 x solar collector system M and N L 8 Connections to the top of the Solar Hot Water Tank This picture shows the connection to...

Page 16: ...lar flow is connected from Point P on the tank to the inlet to the solar pump Point D G U H P U 10 The completed Solar Hot Water Tank assembly The Tank and Solar control kit must be positioned close t...

Page 17: ...on on a hot day the Solar collectors and fittings will be too hot to touch Turn off mains water supply valve Make sure all connections are tightened Make sure all fittings are securely tightened Ensur...

Page 18: ...supplied Tap in the 4 x plastic end caps into the cut off ends of the frame square sections 4 x L shaped brackets attach each collector frame to the Roof Frame With all the evacuated glass tubes remov...

Page 19: ...l 32mm thickness insulation between the Solar Preheat Tank and the Gas Booster Position the Solar Hot Water tank on firm and level ground near an electrical supply Screw the Shut off valve to the outl...

Page 20: ...he sun 14 Priming and filling the system Fit the Solar hot water outlet connector to the Solar Tank using thread tape Point H Connect the DuoValve P N DUO00A and the water Pressure Limiting Valve P N...

Page 21: ...e piece SL I 1500 Collector tubes U 1500 16 MODEL Suntrap Evacuated U Tube Solar Collector Features Simple structure and stable operation Utilization all year round even in cold climates Can operate w...

Page 22: ...system or a component is replaced by Suntrap the balance of any original warranty will remain effective The replacement part does not carry any additional warranty 14 Suntrap s obligations under this...

Reviews: