14
5-6
MALFUNCTION, INSPECTION, RESOLUTION PROCEDURE
The charging
process is
completed however
workable period is
shortened.
Green LED
illuminates soon
after the start of
charging.
No power supplied.
LED won't illuminate.
Insufficient insertion of Power Plug
into outlet.
Check outlet and securely connect
Power Plug.
TROUBLE
CAUSE
COUNTERMEASURE
Power Cord is broken.
Arrange its repair or replacement.
Check power and other relevant parts.
No power is supplied.
Check the connecting parts and
securely connect them.
Receptacle and Plug are improperly
connected.
Battery Pack is improperly connected.
Check the connecting parts and
securely connect them.
Battery Charger's power source trouble. Arrange a check or repair.
Replace with a new Battery. (See P15.)
Battery nearly dead.
Charge Battery in an ambient
temperature between 5 and 40
℃
.
Ambient temperature is low during
charging.
Battery is normally charged.
Normal.
Battery malfunction.
Replace with a new Battery. (See P15.)
•
For safe handling of Charger, be sure to read the
instructions thoroughly before using Charger.
• Charger is only to be used with an AC115V/230V
power source. Never connect Power Cable to any
other power source specification.
• Extended charging may reduce Battery capacity re-
sulting in shorter Battery life.
•
Battery and Charger's Output Terminals have polarity.
Confirm that those Terminals are correctly connected
according their polarit
y. Improper connection will
result in a short circuit and cause a cable to melt or
o
ther serio
us charger malfunction.
• Never remove Charger Cover or you will risk re-
ceiving an electric shock.
•
Keep Charger indoors, away from direct sunlight
and water splashes. Neglecting this can cause fire,
electric shock or equipment malfunction.
• As Battery deteriorates, its voltage will fail to reach
normal full-charge voltage
.