30
3.3.8 Start Engine in Cold Weather
1)
Turn the key switch to ON position.
2)
Screw key switch to start position and keep a few seconds to lubricate the hydraulic pump
before engine starts.
3)
Screw key switch anticlockwise to HEAT position, the indicator light will on, after 30
seconds which means the preheating is finished.
4)
When the preheating indicator light is on, start the engine as above mentioned methods.
3.3.9 Adjusting Engine Rev
When accelerator handle is lifted to upmost and engine runs at full load; lower handle to
bottommost, engine runs at minimum load; adjust accelerator between upmost and bottommost
to control engine rev, and also you can screw handle to adjust accelerator imperceptibly.
3.3.10 Stopping Engine
1)
Lower the bucket to ground.
2)
Place the accelerator handle to minimum load position for about 5 minutes.
3)
Screw key switch to “OFF” position to stop engine, and take out key.
4)
Pull pilot control lever to LOCK position.
Don’t stop engine directly when it is fully loaded,
stop engine after 5 minutes minimum load operation
to unload the heat load and avoid possible damage
to engine. If engine stops with load, remove load
and start engine at once. Operate engine for 1
minute at half speed before loading.