OPERATION & MAINTENANCE MANUAL SWE18UF
29
All filled hydraulic oil must pass through returning oil filter. The daily maintenance should
be taken in accordance with the criterion.
Engine starting and stopping label
:
3.3.6 Before Starting Engine
1)
Keep pilot valve control lever locked and pilot handle & travel pole neutral. Operator sits on
seat.
2)
Turn the key switch to ON position, all indicator lights come on except engine hour meter
and LCD module, buzzer tweets, self-inspection is finished after 2 seconds and the monitor
system is on normal working condition.
3.3.7 Starting Engine
1)
Keep pilot valve control lever locked.
2)
Turn the key switch to ON position.
3)
Honk the horn to warn surrounding people.
4)
Start engine by turning key switch clockwise to START position. Release key, the switch
will return to ON position.
In order to avoid damage of starter, never operate motor starter for
10 seconds or more every time. If the engine can’t start, turn the
key switch to OFF position and wait at least 2 minutes, then try again.
After the wrong start, the engine should be stopped completely, then
you can turn key switch, otherwise it may damage starter.
If there is a flicker in monitor, stop engine at once and check the
reason.