OPERATION & MAINTENANCE MANUAL SWE18UF
61
oil.
7)
Re-fit on oil drainage port plug.
8)
Take out filler cap. Fill in gear oil until the oil level is equal to the oil filler hole.
4.2.4 Fuel Oil System
Parts name
Qty
Interval (hours)
8
50
100
200
500
1000
2000
1. Vent fuel tank sediments
1
△
2. Check and vent sediments in
precipitator
1
△★
△
3. Vent water and sediment in
water segregator
1
△
4. Replace fuel filter
1
△
5.Check
fuel hose
Leakage, crack, etc.
△
Crack,
distortion,
etc.
△
Recommended fuel:
Please use high quality diesel fuel (GB2520 in
normal condition; 10 for the winter) only, do not use
kerosene.
Fueling
1)
Refer to “stop engine” chapter, park the excavator properly and turn off the engine
correctly.
Check and vent the precipitator every
50 hours, and replace it every 1000
hours.
Be caution about the fuel. Turn
off engine before fueling. Do not
smoke while fueling the fuel tank
or work near the fuel system.