OPERATION & MAINTENANCE MANUAL SWE18UF
72
686kPa to clean air filter element
⑦
, first, blow
along the flute of interior of the filter element, than
blow from outside, finally blow from the interior.
13)
Light a lamp in the filter element, check the filter element
⑦
, replace it immediately
whether any hole or spot is detected.
14)
Remove the cloth or adhesive tape of step 10.
15)
Install filter element
⑦
.
16)
Install dust collection cup
⑥
, keep the “TOP” mark up,
then lock the lock catch
⑤
.
Connection pipeline between air filter and engine
Check seal…every day
Replace…When pipeline has crack and air leakage
4.2.7 Cooling System
Parts name
Qty
Interval (hours)
8
50
100
250
500
1000 2000
1. Check cooling water level
1
▲
2. Check and adjust fan belt
tension
1
※1
▲
3. Replace cooling water
--
4. Clean radiator
and hydraulic oil
cooler core
interior
1
△※3
exterior
1
When replacing cooling water
Decrease pressure of compressed air,
keep other people away from operation
site, beware of flying debris and wear
personal safety implements.
FIG.100
FIG.98
Never start engine when the
hydraulic oil tank is empty.
If bad airproof or crack occurs
on connection pipeline, dirty
air will enter and damage engine.
FIG.100
FIG.98
Never start engine when the
hydraulic oil tank is empty.