30
5.3.4
Range of the measurement field
The maximum distance for contour measurement at a reflectance factor of 80% (white
gypsum) is 50m.
a = Detection zone
b
Fig. 5.3-2:
Detection of objects depending on the reflectance factor. The reference
point of the distance measurement is the axis of the rotating mirror.
5.3.5
The
SD3-A1
is equipped with a selectable dust algorithm to ensure optimum freedom
from interference.
The following detection zone additions must be taken into account:
Activation and deactivation of the function is performed by
SD3SOFT
.
Addition Z
SM
if dust
suppression is deactivated
83mm
Addition Z
SM
if dust
suppression is activated
83mm (for a detection zone size < 3.5m)
100mm (for a detection zone size
3.5m)
Remission in %
= Measurement field
Required detection zone additions Z
Summary of Contents for SD3-A1