37
Safety notes:
Automatic startup / restart must only be used in cases where there is absolutely no
possibility that the effective detection zone could be entered or bypassed in some other
way. Depending on the hazard assessment, visual and / or acoustic startup warnings
should be provided.
The
SD3-A1
is equipped with a restart interlock function. You can select or deselect this
function as needed to connected restarting of the machine to a manual approval. It affects
all detection zones and does not depend on any detection zone changeovers. For
information on how to configure the scanner appropriately, please refer to
SD3SOFT
(Section: “Safety-relevant parameters” folder).
If parameters are set for the function “Manual restart”, the required enable from the
startup / restart button affects all detection zones and is independent of any detection
zone changeover. If the current detection zone is manually enabled, this enable also
applies even if the system switches to another detection zone and this detection zone
becomes free! If startup / restart interlock is in effect in the current detection zone, it is
also in effect for the other detection zone to which the system switches even if this
detection zone is free.
5.4.7 Restart
interlock
The restart button must be mounted so that
The button refer to the areas to be enabled in a easily understandable manner.
Please comply with the safety notes in Chapter 3 and 5.4.6.
x
the entire danger zone (or detection zone area ) can be viewed from the operating
position.
x
it is not possible to directly step or reach into the danger zone or danger point from
the operating position.
Summary of Contents for SD3-A1
Page 1: ......
Page 12: ...12...
Page 40: ...40 Fig 5 4 5 Considering the maximum measurement distance when safeguarding an area...
Page 60: ...60 Fig 6 2 1 Example of a zone pair changeover for an AGV on a curved route...
Page 61: ...61 Fig 6 2 2 Example of zone pair changeover with combined with reducing speed of the AGV...
Page 101: ...101 13 13 Dimensional drawings of the SD3 A1...
Page 102: ...102 13 14 Dimensional drawings of the mounting system...
Page 106: ......