Regular tests by a person qualified and authorized to perform the
task
Regular tests must be performed taking into consideration applicable local requirements,
especially for guidelines on machines and using work material and work safety
guidelines. The purpose of these tests is to discover changes (for example lag times) or
manipulations on a machine, vehicle or piece of safety equipment.
To do this, see the checklists under Chapter 11.5 or 11.6
11.4
Daily test by with test piece performed by responsible operating
personnel
The
SD3-A1
is a safety-oriented laser scanner of Category 3. It is extremely important,
however, to check the effectiveness of the detection zone with the test piece daily or after
a shift change. This ensures that if the parameters or operating mode is changed, the
protective function is ensured at every point in the detection zone.
x
Have the effectiveness of the safety equipment checked within the required periods,
but at least once a year by a trained and knowledgeable person.
x
The checklists mentioned above are ideal for regular tests, especially checks for
safety-related changes to the machine, the vehicle or the piece of safety equipment.
Summary of Contents for SD3-A1
Page 1: ......
Page 12: ...12...
Page 40: ...40 Fig 5 4 5 Considering the maximum measurement distance when safeguarding an area...
Page 60: ...60 Fig 6 2 1 Example of a zone pair changeover for an AGV on a curved route...
Page 61: ...61 Fig 6 2 2 Example of zone pair changeover with combined with reducing speed of the AGV...
Page 101: ...101 13 13 Dimensional drawings of the SD3 A1...
Page 102: ...102 13 14 Dimensional drawings of the mounting system...
Page 106: ......