3) Checking the condition of the scanner
4) Inserting the new optical window
Please do not fail to observe:
Check the mirror, optics and housing parts to
make certain they are free of dust. Dry if
necessary with a dry, oil-free, light jet of
compressed air with appropriate components.
Do not touch any parts in the device.
Avoid leaving fingerprints (grease from
fingers may cause the device to function
improperly).
Hold the new optical window by the sides
and carefully insert it in the correct
position, pressing the optical window
together slightly as you do so. Make
certain the rubber seal is not damaged.
Make certain it is in the groove in the
housing designed for that purpose.
Check to make sure the optical window is
seated correctly. There should be no gap
between the optical window and the
housing that lets light through.
Then fasten the new optical window in
place again with the fastening straps. As
you screw in the screws, you can apply a
little pressure on the outermost edge of
the optical window with your thumbs. The
new fastening strap (which has been
available since 2002) is the one to use.