background image

LIT11TC

 

DUO THERM

Thermometer Operating

Instructions

SEALED UNIT PARTS CO., INC.

2230 Landmark Place • Allenwood, NJ 08720

(732) 223-6644 • Fax: (732) 223-1617 • info@supco.com • www.supco.com

ADD VALUE

In MAX, MIN, DIF

AVG mode:

In all modes : First

hold on the Meas.

key (   )

Press Up key (   ) for 

LOCK mode 

ON/OFF. The lock mode is particularly useful for

continuous monitoring of temperatures for up to 60 minutes.

Press Down key (   ) for 

°C or °F transferred

.

and Press Up key (   ) for 

backlight function 

ON/OFF.

and press Down key (   ) for 

laser fuction

 ON/OFF.

** The thermometer will automatically shut off if left idle for more than 60 sec, unless in PRB mode.

     (In PRB mode it will shut off if left idle for more than 12 minutes.)

2

4

4

2

9

Here will show the emissivity data. (The default emissivity is 0.95.)

Press Mode key (   ) for the 

Maximum (MAX), Minimum (MIN), different between MAX and MIN

(DIF) and Average (AVG) modes. During the measurement, the special modes reading will be

displayed beside the mode icon.

Press Up key (   ) or Down key (   ) to change the 

High Alarm (HAL) or Low Alarm (LAL

). then

press Meas. key (   ) to confirm it. For example: When reading 80.6°F <LAL 80.9°F the low icon

will flash and you will hear a beep sound.

Connect the thermocouple with thermocouple socket (   ) and put the probe in/on the target, the

thermometer will display the temperature automatically without pressing any button. To see the

minimum or maximum data during the probe measurement, please hold down the Up key (   )

or Down key (   ).

    After measuring high temp, the probe may remain HOT for awhile.

Press Emissivity key (   ), then press Up key (   ) or Down key (   ) to 

set the emissivity

, then

press Mode key (   ) to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E).

Press Mode key (   ) for scrolling more display function as follows.

1

4

2

5

4

2

9

10

4

2

5

5

(

(

0$;

0,1

GL)

$9*

+$/

/$/

35%

Simply aim the thermometer at the measure

target with Lens (   ) and press Meas. key (   )

to display the surface temperature.

The distance: Spot is 11:1, Please make sure

the target area is within the field of view.

Function

Press

 

Emissivity key (   ) for setting

the  emissivity.

7

1

The LIT11TC is a non-contact infrared thermometer with additional K-type thermocouple. There are many

mathematical modes for the infrared function. Please remember to keep away from children and don’t use it for

safety  related  applications.

+2/'

ƒ

)

'HIDXOW6FUHHQ

(PLVVLYLW\

.H\

'RZQ.H\

/&'

0RGH.H\

%DWWHU\

&RYHU

,QIUDUHG/HQV

/DVHURSWLRQ

0HDV.H\

7KHUPRFRXSOH

6RFNHW

8S.H\

9