4-14
Publication: 0028607
SEWER CLEANING — TYPICAL SEQUENCE
4
Water Lance Operation
The truck is equipped with a water system used for
loosening soils, for wetting down dry materials, and for
general cleanup.
WARNING
1.
Start the truck engine and allow it to idle. Make sure
the parking brake is set and the wheel chocks are
positioned. Place the transmission into neutral (N).
2.
Inside the truck cab, locate the WORK MODE switch
for the hydraulic pump and verify that the valve for the
lance is in the CLOSED position.
3.
Pull out the hose from the spring return reel located
on the right side of the truck and attach the lance gun
and the appropriate extensions along with the
appropriate lance.
WARNING
4.
Turn the water pump on by turning the water pump
speed dial on the front control panel clockwise to the
desired water pressure, or by pressing and holding
the pendant SHIFT switch on either pendant while
pressing the WATER INCR button.
WARNING
5.
Firmly grab the lance with both hands and point it in
the direction of the work to be done. Squeeze the
trigger on the lance and begin operation. Releasing
the trigger will shut off the flow of water through the
lance.
WARNING
6.
When done using the lance, shut the water pump off
by turning the water pump speed dial fully
counterclockwise or by pressing and holding the
pendant shift switch while pressing and holding the
WATER DECR button.
7.
Disengage the hydraulic pump by depressing the
brake pedal, putting the transmission in neutral (N),
and putting the truck in road mode.
8.
Point the lance in a safe direction and pull the trigger
to release any pressure inside the line. Once the
pressure is reduced to zero, you can disconnect the
extensions and lance from the hose.
9.
Store the hose, lance, and extensions in their proper
locations.
10. Turn the wired pendant OFF before moving the truck.
CAUTION
Never point the discharge flow of water from the
lance toward a person since serious injury could
result. Always make sure your feet are firmly
planted and you are securely holding the lance
with both hands before operating the lance.
Only use the nozzles with urethane coatings that
are fully intact to protect against damaging
exposed lines. Never hold the lance stationary
while pointing toward any pipe or conduit since it
could penetrate them. Always keep the lance
moving. Failure to comply with these safety
precautions could result in personal injury and/or
property damage.
Always wear a full face shield with eye protection,
safety shoes, and gloves. Make sure all skin is
covered by work clothes. There could be flying
material from the lance as the water stream
strikes the soil. Failure to comply with the above
could result in serious injury or death.
Never block or tie back the trigger on the lance
since this is a safety device that allows the water
stream to be instantaneously shut off if the need
arises. Failure to comply could result in personal
injury.
Never exceed the pressure rating of your system.
Super Products supplies systems that are rated
at 2000, 2500, and 3000 PSI. Know which system
you have. If you have any questions, contact
Super Products. Failure to comply could result in
personal injury or property damage.
Summary of Contents for Camel 1200 (Dump Body)
Page 1: ......
Page 2: ......
Page 4: ......
Page 62: ...1 52 Publication 0028607 SAFETY 1...
Page 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...