2-6
Publication: 0028607
PRE-OPERATION
2
Figure 2-9
2.
Route the pendant cord to the work area. Care
should be taken when running the pendant cord to
the work area from the truck so that the cord will not
be run over and/or damaged.
3.
If the safety person observes an unsafe or dangerous
situation of any type, he/she should immediately
press the OPEN vent door button on the remote.
Only after all potential dangers have been resolved
should the vent door be closed and normal vacuum
operations be continued. The safety person should
continue to be in a position to observe all vacuum
hose operators until those operators have moved a
safe distance from the end of all vacuum work hoses.
DANGER
Figure 2-10
4.
After the vacuum operation is completed and the
vacuum pump is shut down, properly store the
pendant to prevent damage when truck is being
moved.
Testing of the Remote Operated
Vacuum Vent Door
NOTE
The following test should be done every time the
wired pendant remote control or wireless pendant
remote control is put into use or every two hours
during operation, whichever is more frequent.
Testing with Wired Pendant Remote Control
1.
Visually inspect the pendant cord, electrical plug, and
control switch for damage. Repair or replace as
necessary.
2.
If the pendant is not currently plugged in, insert the
electrical plug on the end of the pendant cord into the
socket located on the right side of the front control
panel or the left side of the curbside control panel.
3.
Make sure the emergency stop button (1) is not
activated.
4.
Turn the OFF/ON/SHIFT switch (2) to the ON
position. The STATUS light (3) will flash green, and
the A light (4) will turn solid red.
5.
Start up the vacuum pump per operating procedure
outlined in this manual.
6.
With the truck at full vacuum, press the VENT OPEN
button (5) on the remote and verify that the vacuum
vent door has opened. Press the VENT CLOSED
button (6) and verify that the vacuum vent door has
closed.
7.
When the test is complete, shut down the vacuum
pump.
Pendant Cord Socket Curbside Control Panel
Never move close to the end of any vacuum hose
unless the safety person has the remote and is in
a position to observe all operators.
Failure to comply with this could result in serious
personal injury or death.
2
Summary of Contents for Camel 1200 (Dump Body)
Page 1: ......
Page 2: ......
Page 4: ......
Page 62: ...1 52 Publication 0028607 SAFETY 1...
Page 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...
Page 106: ...4 18 Publication 0028607 SEWER CLEANING TYPICAL SEQUENCE 4...
Page 118: ...5 12 Publication 0028607 WATER RECYCLING SYSTEM 5...
Page 132: ...6 14 Publication 0028607 LUBRICATION AND MAINTENANCE 6...
Page 156: ...i vi Publication 0028607 IX...
Page 157: ......