3-6
Publication: 0028607
CONTROL SYSTEM OPERATION
3
4.
A red EMERGENCY STOP Active error message will
be displayed on the display screen, and the alarm will
sound. The alarm can be silenced by pressing the
OK button on the front panel.
Figure 3-10
5.
To return to full operation, reset the system by
twisting the red emergency stop switch clockwise.
VAC/DUMP MODE Rocker Switch
• The VAC/DUMP MODE rocker switch (1) selects
either vacuum mode or dump mode. One of these
two modes must be selected before any other
function is selected.
• Vacuum (VAC) Mode — Enables the vacuum,
boom, hose reel, and compaction functions and
disables tailgate and body functions.
• Dump Mode — Enables tailgate, body, and
water pump functions and disables the vacuum,
boom, hose reel, and compaction functions.
• The VAC/DUMP MODE rocker switch LEDs will not
illuminate until the mode switch is moved to WORK
mode. Once in work mode, both VAC/DUMP MODE
rocker switch LED colors will illuminate red until
either VAC or DUMP mode is selected. A green LED
will illuminate for the selected mode.
VENT DOOR Rocker Switch
• Opens or closes the vacuum vent door.
• The switch giving the last command is in control until
a different panel or pendant switch is used.
Vent door positions
• Truck Off — vent door is open
• Truck Start, Driving — vent door is closed
• Work Mode – vent door is open
• VAC Mode – vent door is open. Vent door can
be open and closed in blower mode via the front
control panel and the wired or remote control
pendant.
RECIRCULATE Rocker Switch (Option)
Winter recirculation mode is used to circulate water
through the water system plumbing and water tanks to
prevent freezing. Winter recirculation is meant to run
when the truck is either idling or driving on the road.
When the winter recirculation switch is switched ON, the
water pump hydraulic pumps are engaged. The water
pump will run a minimum of 10 GPM (gallons per minute)
while at idle. Faster engine RPM while in road mode will
cause the water pump to pump up to 30 GPM or more
due to the faster running hydraulic pump.
RECYCLE Rocker Switch (Option)
The RECYCLE rocker switch activates the water
recycling system that filters sewer water and supplies it to
the high-pressure water pump for reuse during sewer
jetting work. This system allows the operator to continue
working by recycling sewer water and not having to shut
down and travel elsewhere to refill with potable water.
See Chapter 5, “Water Recycling System”.
BOOM LIGHT Rocker Switch
Boom lights can only be turned on when in work mode.
VAC BOOST Rocker Switch (Option)
Pressing the top of this switch will close the vacuum
booster door and build vacuum in the debris body as long
as this switch is pressed. Releasing the switch will open
the vacuum booster door and cause a huge rush of air
through the boom hose.
Vacuum boost states are the following:
• Works when cab panel mode switch is set to work
and when front panel mode switch is set to VAC.
• Works when in full VAC mode.
Figure 3-11
Emergency Stop HMI Screen
ok
Front Control Panel Rocker Switches
1) MODE Rocker Switch
4) RECYCLE Rocker Switch
2) VENT DOOR Rocker Switch
5) BOOM LIGHT Rocker Switch
3) RECIRCULATE Rocker Switch
6) VAC BOOST Rocker Switch
1
2
3
4
5
6
Summary of Contents for Camel 1200 (Dump Body)
Page 1: ......
Page 2: ......
Page 4: ......
Page 62: ...1 52 Publication 0028607 SAFETY 1...
Page 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...
Page 106: ...4 18 Publication 0028607 SEWER CLEANING TYPICAL SEQUENCE 4...
Page 118: ...5 12 Publication 0028607 WATER RECYCLING SYSTEM 5...
Page 132: ...6 14 Publication 0028607 LUBRICATION AND MAINTENANCE 6...
Page 156: ...i vi Publication 0028607 IX...
Page 157: ......