CONTROL SYSTEM OPERATION
Publication: 0028607
3-9
3
Adjust Valve Settings and Operation
These setting are used to either increase or decrease the
operating speed of the controls listed per the operator’s
preference.
1.
Press the MAIN MENU button three times.
2.
Select Valve Settings and press OK.
Figure 3-13
3.
Within the valve settings screen, use the up and
down arrows to select the required function and the
left and right arrows to select the MIN% and MAX%
required selections and then press OK. Use the up
and down arrows to set the required percentages
and press OK.
Figure 3-14
4.
Repeat the procedure to adjust all other required
functions and percentages.
NOTES
• Min./max.percentages are relative to 100% total. For
example, 20% max. would be 120% total function
change. Default min./max. percentage settings are
set before delivery at the Super Products factory.
• When adjusting the speed offsets for use with the
optional remote pendants the MIN% setting will
control the speed for the first four seconds that the
button is depressed, after the first four seconds the
MAX% setting will then control the speed.
ok
ok
Summary of Contents for Camel 1200 (Dump Body)
Page 1: ......
Page 2: ......
Page 4: ......
Page 62: ...1 52 Publication 0028607 SAFETY 1...
Page 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...
Page 106: ...4 18 Publication 0028607 SEWER CLEANING TYPICAL SEQUENCE 4...
Page 118: ...5 12 Publication 0028607 WATER RECYCLING SYSTEM 5...
Page 132: ...6 14 Publication 0028607 LUBRICATION AND MAINTENANCE 6...
Page 156: ...i vi Publication 0028607 IX...
Page 157: ......