Updated: 10 October, 2009
Page 11
REF: REI-90-0611
Printer Ribbon Setting
8.
Mould Removal and Replacement
ELECTRICAL HAZARD
Always REMOVE the machine from the power outlet before performing any maintenance or
cleaning works.
BURN HAZARD
• Cleaning and maintenance should be performed by your trained personnel only
• Allow unit to cool at least 90 minutes before normal cleaning
• Always wear hot pad gloves when performing machine cleaning.
6.1
Upper Mould
Sealing and Cutting Function
Standard Upper mould (i.e. without the gas flushing option) performs the sealing and the
cutting function at the same time.
Removing and Exchanging
Mould can be removed for cleaning or exchange by (see images below) :
•
Removing the gas flush tube
•
Removing the thermocouple and wiring
connection