Updated: 10 October, 2009
Page 14
REF: REI-90-0611
system error.
2 P.C.B error
2 Change P.C.B
Temperature control
system error.
Heater not turned on
after power is on.
Power on failed
P.C.B error
Reboot the power on key. If fail
again then.
Change P.C.B
Heating circuit error.
Heat up time over 7
minutes,
cannot reach set
temperature.
Heater error
Heating wire error
Change new heater.
Change new heating wire.
E01
b. Temperature too
high (200 ), the
heater remains on
after set temperature.
Power off wait till temperature
lower than set value then re , start
the power again. If happen again
replace the PC Board.
E02
Upper cylinder
operating system
error.
No air pressure
Cylinder sensor error
Open air valve on compressor.
Check the cylinder position
sensor.
Error appears right after
the power on
Check the out position micro
switch.
Check the micro switch wire.
Replace the PC board.
Error appears when the
lower mould moves out
half way
Check the jack up system. The
bearing roller may go out off the
slide way.
E03
Lower mould system
error.
Error for un-smooth lower
mould movement.
Clean both the slide ways and
bearings of the lower mould
system. Or replace the dirty
bearing.
E04
Sealing film is used
up, or eye-mark
sensor error.
Sealing film dressing
error.
Check the film eye-
mark sensor
Correct the film dressing.
Clean, adjusting the eye-mark
sensor
Change new sensor.
Lower mould does not
move in position
E05
Lower mould
Position switch error
Lower mould moved in
but upper mould does not
press down
Check the micro switch wire and
micro switch
Change the wire or micro switch if
failed again.
E06
Upper mould press
down error.
No air pressure
Check the air cylinder and air
pressure system.
E07
Safe door is touched
or collided.
Safety door error
Adjust the switch of Safety door.
E19
P.C board error.
P.C.BOARD error
Change new P.C.BOARD
ITEM
POSSIBLE CAUSE
SOLUTION
(1)
The cutter cut the
edge of container
The upper and lower mould
misalignment.
Check both the front and rear
micro switch of the lower mould.