background image

Updated: 10 October, 2009

Page 5

REF: REI-90-0611

2.1 Specifications

REI-90F

Machine Construction
Output Capability
Air Requirement
Machine Dimension
Machine Weight
Power Requirement
Roll Diameter
Roll Width

Stainless Steel/ Aluminium Alloy
Up to 8 cycles per minute
2HP (600KPa, 20L/M, 80 psig)
~ 430Lmmx660Wmmx710Hmm
~ 80 kg
1Phase, 220-240Vac @ 10Amps
2 inches diameter
280mm diameter

Machine Specification is dependent on the size of the container and the machine applications. Cycle
time is reduced with the introduction of the gas flushing.

MAP

Inert Gas Requirement
Oxygen Residual Capability
Inert Gases

80 psig and 5 scfm
Achieved < 2%*
Nitrogen, Carbon Dioxide, Oxygen, Noble Gases

The oxygen residual capability could be adjustable and is dependent on the container size, the type of
product application, flushing dwell time requirements and the gas purity used.

3.

Operation

a.

After connecting the plug to the AC power source, the power indicator light will be turned
“on”.

b.

When the

power on” key is pressed, the microcomputer will automatically check if all

sensors and switches are functioning. When all are operational, the lower mould will move to
the initial eject position.

This power on checking procedure will take approximately five

seconds.

The sealing film system is also checked by the machine control system at all times.

c.

Once the power has been switched on, the first heating time interval will take approximately
five minutes, (this depends on the set temperature, and the environment temperature). After
reaching the set temperature, the heating indicator light will switch “off” automatically.

d.

The machine can be operated manually or automatically (and this can be set on the control
panel). On MANU (manual) mode, the operator needs to press the MANUAL button to
perform the sealing function. During AUTO mode, the container photo sensor will be
triggered to perform the sealing function.

e.

During the sealing process, the upper mould is pushed down against the lower mould using a
constant air pressure to obtain a fast and even sealing . When the sealing film is heat sealed
onto the container, a cutter blade concealed in the upper mould will cut the sealing film to its
predefined shape.

f.

The lower mould will eject automatically after the sealing and cutting function; ready for the
next cycle.

g.

Remove the container after sealing and perform (e).

h.

To shutdown the machine, turn off by pressing the Power key, and then disconnect the plug to
the AC power

Summary of Contents for REI-90F

Page 1: ......

Page 2: ...oroughly read this manual first CAUTION BURN HAZARD Cleaning and maintenance should be performed by your trained personnel only Allow unit to cool at least 90 minutes before normal cleaning If hot mac...

Page 3: ...on 5 4 Control Panel 6 5 Resetting Computer Program 7 6 Roll Film Set Up 10 7 Date Printer Coder 10 8 Mould Removal and Replacement 11 6 1 Upper Mould 11 6 2 Lower Mould 12 9 Maintenance and Cleaning...

Page 4: ...0L M Sealing moulds can be exchangeable for different tray for about 5 minutes only Safety Features gearless construction and safety front panel Container Photo Sensor or Manual option Film Sensor or...

Page 5: ...ld will move to the initial eject position This power on checking procedure will take approximately five seconds The sealing film system is also checked by the machine control system at all times c On...

Page 6: ...for use TEMPERATURE CONTROL This is to manage the temperature setting in degrees centigrade o C Up and Down to increase or decrease one unit of value Polypropylene PVC or PET films could have the def...

Page 7: ...heater 030 220 C 130 P 1 3 Printer heater 030 220 C 100 P2 Calculator lock open Lok Lock can t rest Opn Open can set Opn P3 Sealing time 001 030 unit 0 1sec 3 sec 010 P4 Cup waiting time 000 030 unit...

Page 8: ...position Use keys to increase or decrease the value by one unit 0 1 second Generally the value is assigned between 005 and 015 It is set at 010 1 sec at the factory This function based on the whether...

Page 9: ...and the right display will give a value between 001 199 set the correct value for the distance between the 1st printing and 2nd printing The 1st printing is operated with the sealing mould simultaneou...

Page 10: ...bbon Ribbon Color 100 meters Black standard Maximum Number of Alphanumeric per line 9 e g 20060918 EXP060918 Temperature Setting adjustable 50 100 C Default 100 ON OFF Using the Control Panel Printer...

Page 11: ...your trained personnel only Allow unit to cool at least 90 minutes before normal cleaning Always wear hot pad gloves when performing machine cleaning 6 1 Upper Mould Sealing and Cutting Function Stand...

Page 12: ...osition for the sealing and the cutting function Exchanging Simply remove the black screw from the bottom of the lower mould and pull out the lower mould 9 Maintenance and Cleaning ELECTRICAL HAZARD A...

Page 13: ...ould cylinder sensor or limited switch Top area error E E03 Limited switch error Lower mould output stop F E04 Sealing film is used up out off position or eye mark sensor error G E05 Limited switch er...

Page 14: ...mould moves out half way Check the jack up system The bearing roller may go out off the slide way E03 Lower mould system error Error for un smooth lower mould movement Clean both the slide ways and b...

Page 15: ...nsor position and clean the sensor Adjust the film roll and clamp 3 Poor sealing performance Film material is not suitable for the container The heater is not clean Sealing time is too short Cutter is...

Page 16: ...Updated 10 October 2009 Page 16 REF REI 90 0611 11 Wiring Diagram...

Page 17: ...Updated 10 October 2009 Page 17 REF REI 90 0611...

Reviews: