background image

11

VentilatorUserGuide-718WT.doc

REV 02/03/05

9. Warranty

Limited Warranty

Five Years

Super Vacuum Manufacturing Company warrants that the equipment is free from defects in materials and workmanship when used and operated for a

period of five years. The responsibility of Super Vacuum Manufacturing Company under this limited warranty is limited to the repair and replacement

of any parts which are found defective and which are returned to Super Vacuum Manufacturing Company at 

3842 Redman Dr, Fort Collins, CO 80524

with transportation charges prepaid (C.O.D. shipments will not be accepted).

Prior  to  returning  defective  parts  to  SUPER  VACUUM  MANUFACTURING  COMPANY,  the  original  purchaser  shall  make  a  claim  in  writing  to

SUPER VACUUM MANUFACTURING COMPANY at the above address indicating the model number and type of defect. No parts or equipment will

be received by SUPER VACUUM MANUFACTURING COMPANY for repair or replacement under this warranty without specific written authority

from it in advance.

Any parts damaged by improper installation, overloading, abuse or accident of any type or cause are not covered by this warranty.

All equipment manufactured by us is pre-run and tested before leaving our plant, and is shipped in good working order and condition. We therefore

extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase:

1.

 

This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental

and  consequential  expense  and  loss,  nor  does  this  warranty  apply  to  equipment  where  alterations  have  been  executed  without  our

knowledge or consent. These conditions are readily discernable when the equipment is returned to us for inspection.

2.

 

On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the

manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local

business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.

3.

 

If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume

no responsibility for such damage.

4.

 

Any service other than our Authorized Service voids this warranty.

5.

 

This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of

MERCHANTIBILITY or FITNESS for a particular purpose.

Summary of Contents for 718WT

Page 1: ...1 VentilatorUserGuide 718WT doc Last printed 02 03 05 11 41 AM VENTILATOR USER GUIDE MODEL 718WT...

Page 2: ...e take the time to read this manual before operating the ventilator Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 3 2 GENERAL DESCRIPTION AND SPECIFICATIONS 4 3 PR...

Page 3: ...f we filed claim here it would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor an...

Page 4: ...notification Refer to model decal affixed to ventilator to determine actual specifications This ventilator is designed for high powered air movement Super Vac s propeller produces a greater intake of...

Page 5: ...oper inlet or outlet guards in place If guards are missing or damaged contact factory for replacements Do not place fingers or other foreign objects through inlet or outlet guards Should a foreign obj...

Page 6: ...raphs allow you to establish with precision the best utilization of the apparatus Graph 1 depicts rotational speed and water consumption depending on input feed pressure Graph 2 depicts the usable hor...

Page 7: ...05 11 41 AM Inlet Pressure Water Flow Air Flow BAR PSI GPM LPM CFM CMH 3 3 50 55 208 5168 8781 6 7 100 78 295 10112 17179 10 0 150 98 371 16178 27487 13 3 200 110 416 19100 32450 16 7 250 130 492 2247...

Page 8: ...lt positions If your application requires the use of the two back tilt positions the inlet and discharge blocks on the water turbine motor may be rotated 90 degrees Using a 3mm hex key not supplied re...

Page 9: ...NG REDUCER 3 4 X 1 2 17 032 11133 2 3 8 16 NYLOK HEX NUT ZINC 18 008 14624 1 718 BRAKE BAR FINISHED 19 008 14622 1 VENTILATOR BRAKE MOUNT 1 20 008 14623 2 VENTILATOR BRAKE MOUNT 2 21 019 16020 2 SUPPO...

Page 10: ...10 VentilatorUserGuide 718WT doc REV 02 03 05 8 Exploded View Drawing...

Page 11: ...fore leaving our plant and is shipped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original d...

Page 12: ...c REV 02 03 05 10 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman D Fort Collins CO 80524 Phone 1 800 525 5224 970 297 7100 FAX 970 297...

Reviews: