5. Operation

Check ventilator inlet and outlet guards for obstructions. Check and remove from immediate surrounding area any objects that

could be drawn into the ventilator intake.

Place ventilator in desired location before connecting to power supply.

Extend and place any flexible duct as required. Use caution not to direct toxic fumes into confined spaces with the ventilator.

Please refer to the 

Super Vac Training Manual for Smoke Ventilation

  for  comprehensive  instruction  on  effective  ventilation

practices.

Insert power cord plug into 120 VAC power receptacle to begin ventilation.

To stop ventilation remove power cord plug from AC power receptacle.

6. Maintenance and Repair

Maintenance should only be performed by experienced and trained personnel.

Be sure the ventilator is disconnected from the power source before performing any maintenance or repair.

The motor is of heavy duty ball bearing construction. The unit is completely sealed and requires no lubrication for the life of the

motor.

The  ventilator  blade  should  be  specially  checked  for  build-up  of  material  or  dirt  which  may  cause  an  imbalance.  Excessive

imbalance  can  lead  to  accelerated  wear  on  motor  bearings  and  vibration.  Remove  ventilator  guards.  Clean  blade  and  inside

housing with mild detergent and water. Do not use abrasives, sharp instruments or caustic solvents that may scratch or damage the

aluminum alloy blade..

Intake  and  exhaust  guards  are  not  interchangeable.  When  replacing  guards  after  cleaning,  position  them  with  the  rings  to  the

outside with the row of spot welds holding the rings on the bottom.

Summary of Contents for P244S

Page 1: ...P N 008 15094 VENTILATOR USER GUIDE MODEL P244S...

Page 2: ...r Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 2 GENERAL DESCRIPTION AND SPECIFICATIONS 3 3 PRODUCT SAFETY PRECAUTIONS 4 4 BEFORE OPERATING VENTILATOR 4 5 OPERA...

Page 3: ...would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor and in contact with the loc...

Page 4: ...signed for high powered air movement Super Vac s patented propeller produces a greater intake of air and eliminates turbulence at the tips The high velocity screw action sweeps air back over the motor...

Page 5: ...o not place or operate ventilator on unsteady tables slanted surfaces or other unstable surfaces Never handle energized power cords with wet hands Never let extension cords or plug connection lay in w...

Page 6: ...le 6 Maintenance and Repair Maintenance should only be performed by experienced and trained personnel Be sure the ventilator is disconnected from the power source before performing any maintenance or...

Page 7: ...r supply Common causes of motor overheating Power generator not providing constant voltage Ventilators are equipped with AC motors designed to operate on power that falls between 3 of design specifica...

Page 8: ...age requirements When conditions require the use of reeled cable unreel all cable and place on the ground in very loose overlapping non uniform coils Units1 WATTS2 Minimum Wire Gauge Maximum Cable Len...

Page 9: ...plant and is shipped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase...

Page 10: ...e PS Series doc REV 08 13 03 11 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc 3842 Redman Dr Fort Collins CO 80524 Phone 1 800 525 5224 970 297 71...

Page 11: ...5 16 18 NYLOK HEX NUT ZINC 13 024 10527 4 FEET 1409 W RECTANGULAR 14 032 10698 8 8 32 X 1 2 PHIL PH MS ZINC 15 032 10695 8 8 32 HEX NUT ZINC 16 018 10389 1 HOUSING 24 STEEL PAINTED 17 005 10134 1 HEY...