6
3.
Maintenance and Repair
•
Precauctions
1. Turn The Power To OFF Position & Disconnect The Power
2. Drain AllThe Fluid From The Filter And Close The In/Outlet.
3. Service personnel Must Wear Protective Clothing.( Gloves Boots
Goggle & Etc.)
4. Make Sure The Pump Is Not Siphoning From The Tank.
*
Filter Part
Judging By Visual- Check The Capacity Of Liquid Flowing Out From The Filter.
If The Discharge Is Very Low, Take Apart The Filter Material For Cleaning.
Filter Maintenance
1. Put The Cartridges And Tamis Bags Into 5% HCl Solution. Soak Them
For 3-5 Hours, And Then Clean Them With Water.
*(Please Do Not Scrub The Cartridge and Tamis bags)
2. Rinse The Filter Medium With Clean Water.
*3. Filter Maintenance Card (Pg.24)For Routine Filter Maintenance and Request.
*
Do Not Exceed 80% of Its Pressure Range. Barrel Are Design To Withstand
Maximum of 3kg of Pressure.
Judging On Cartridge Replacement
Put The Cleaned Cartridge Into The Filter And Start The Filter.If The
Pressure Increases Quickly,It Means That The Cartridges Are Seriously
Blocked.It Has Become Ineffective, And Must Be Replaced.