Installation, Operation & Maintenance Manual
For IF & IFP Series Models: IF-C8F10, IF-C15F20,
IFP-C15F20, IF-C24F40 & IFP-C24F40
Reduce Particulate, Chlorine, Taste, Odor & Scale
DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION
•
Installation must conform to all local plumbing codes and regulations.
•
Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system.
•
Connect system to cold water supply only! Water temperature must not exceed 100°F/38°C.
•
Do NOT solder plumbing connections attached to the filter housing or inlet valve. High temperature will damage these
components.
•
Do NOT over-tighten fitting connections into inlet valve or housing outlet. Always back-up valves and fittings with a
wrench to avoid turning the valve.
•
Allow a minimum of 3” under the housing to allow for sump removal and filter replacement.
•
Do NOT mount the system near a heat source or above the electrical wiring or any device or area that would be
adversely affected by water.
•
Do NOT mount the system behind equipment. The unit must be easily accessible for filter replacement.
•
Failure to change cartridges per recommended intervals with Supera® replacement cartridges may lead to system
failure and property damage.
Introduction
Your new Supera® IF & IFP Series FoodService Filtration System will cleanse and condition the tap water providing
optimum water characteristics for their specified applications. The result is reduced equipment maintenance requirements,
longer equipment life and improved quality and consistency of your products. Proper system installation and routine filter
changes will ensure years of trouble-free operation and performance.
The Supera® Water Filtration System is built with the finest and most advanced materials and each system is quality
inspected and pressure tested prior to shipment. With proper installation and routine maintenance, you will have years of
troublefree operation.
Please refer to this manual when performing routine filter changes. The instructions make periodic maintenance quick and
easy, and ensure that you will receive maximum benefit from your system.
System Specifications & Dimensions
Inlet/Outlet Connections: 1/2” FNPT
All systems flow left (inlet) to right (outlet)
Operating Specifications
Maximum Pressure:
125 psi/8.6 bar
Maximum Temperature: 100°F/38°C
Capacity: Change filters at gallon rating or at least every 6 months or when pressure gauge needle enters the red zone on the
outlet gauge while water is flowing through the filter system under normal operating conditions.
Model IF-C8F10
Capacity: 15,000 gals./56,800 L
Service Flow Rate: 1.5 gpm/5.7 lpm
Model IF-C15F20
Capacity: 30,000 gals./113,600 L
Service Flow Rate: 3 gpm/11.3 lpm
© Supera, 2013
v1 IFIFPSERIES
Page 1