background image

START UP

 PROCEDURE

 

Bin Control

 Operation

 

The bin control is used to shut the machine off when the bin fills with ice. The bin control must be 
checked upon installation or initial start-up and when performing maintenance. Adjustments are 
not covered under warranty. There is one bin switch for each evaporator. The actuator arm of the 
bin switch comes in contact with the splash curtain. When the bin is full of ice, the splash curtain is 
held open when ice drops off of the evaporator. This releases the 
pressure of the bin switch actuator arm allowing the switch to open. 

Undercounter machines: A thermostatic bin control is used on the 
undercounter models. The bin thermostat is located in the control box 
with a capillary tube, which is in a brass thermo-well mounted to the 
right side of the water trough. 

When ice comes in contact with the capillary tube thermo-well, the bin 
thermostat opens and the machine will shut off. 

Bin Control Adjustment 

All Models (Except Undercounter Models): Check the bin switch for 
proper adjustment by swinging the bottom of the curtain away from the 
evaporator. Slowly bring the curtain towards the evaporator. The switch 
should close when the bottom edge of the curtain is even with the outer 
edge of the water trough. Adjust the switch by loosening the nuts that 
hold the switch in place. Move the switch to the proper position and 
retighten the nuts. Recheck the adjustment. Adjustments are not 
covered under warranty. 

Undercounter Models 

The Bin Thermostat used on these Self Contained Ice Cuber Machines is 
a sensitive device influenced by ambient conditions including altitude 
and temperature. The machine is set up to operate properly at the 
factory for 70°F at sea level. If your ice machine shuts off early, bin half 
full, or doesn’t shut off, bin overflowing, please follow these instructions 
to set the bin thermostat. 

© Supera    

September 2015           

   1

0

Summary of Contents for UIM-240FA

Page 1: ...MANUAL This manual contains important information regarding your Supera unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maint...

Page 2: ...one 866 953 3288 E mail Service SuperaCo com Any service communication must include Model Serial Number A detailed explanation of the issue Keep this manual for future reference The Supera Service Par...

Page 3: ...al evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent The claim should be filed on a form available from the carrier...

Page 4: ...vidually to a floor drain The use of condensate pumps for draining water is not recommended by Supera Supera assumes no responsibility for improperly installed equipment Note The purge drain fitting i...

Page 5: ...of an electrical fire Adjustments Level the machine within 1 8 inch in all directions Check the bin control for proper adjustment Check the water in the water trough for proper level Check the ice bri...

Page 6: ...tion All water supply lines must be installed per local codes Use 1 4 inch O D minimum on air cooled machines On water cooled machines 3 8 inch O D minimum tubing must be run to the condenser The wate...

Page 7: ...OFF WASH Switch is located in the control box Remove the grill screws to access the control box Note This unit does not have a splash curtain This model utilizes a thermostatic bin control in place o...

Page 8: ...This unit does not have a splash curtain This model utilizes a thermostatic bin control in place of a mechanical bin switch ON OFF WASH Switch is located in the control box Remove the grill screws to...

Page 9: ...now supplied to the water purge valve hot gas valve and the harvest motor The water purge valve opens and allows the water pump to purge the water remaining in the water trough removing impurities and...

Page 10: ...vaporators check the freeze pattern of the ice Ice should form evenly across the evaporator Bridge Thickness and Timer Adjustment Once the unit has gone through 1 or 2 harvest cycles verify that the i...

Page 11: ...e capillary tube thermo well the bin thermostat opens and the machine will shut off Bin Control Adjustment All Models Except Undercounter Models Check the bin switch for proper adjustment by swinging...

Page 12: ...the brass thermal well for 3 4 minutes It is imperative that enough ice be used for the 4 Slowly turn the adjustment screw counter clockwise until the machine shuts off If the screw is turned too qui...

Page 13: ...n 2 Check ice bridge thickness 3 Check water level in trough 4 Clean the condenser air cooled machines to insure unobstructed air flow 5 Check for leaks of any kind Water Refrigerant Oil Etc 6 Check t...

Page 14: ...move the splash curtain and inspect the evaporator and water spillway to ensure all mineral residue has been removed 8 If necessary wipe the evaporator spillway and other water transport surfaces with...

Page 15: ...urface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the steel Chlorides break down t...

Page 16: ...rvest or wait for cycle completion 3 Place the ICE OFF WASH switch to the OFF position The switch is located in the control box 4 Disconnect the tubing between the water pump discharge and water distr...

Page 17: ...Service History Model Number Serial Number Date Installed...

Page 18: ...d Under This Warranty SUPERA LLC s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor...

Page 19: ...Supera Customer Care Toll Free Service Line 1 866 953 3288 For additional product and warranty information please visit our website at www SuperaCo com...

Reviews: